Description
Quick Details
MINDRAY BC 5300
MINDRAY BC 5300 VET
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
mindray bc 5300
Auto Hematology Analyzer
Auto Hematology Analyzer
BC-5300
Technical Specifications:
Principles
Flow Cytometry (FCM), Semi-conductor Laser scatter, chemical dye
method, independent Basophil channel
Impedance method for WBC, RBC, PLT counting
Cyanide-free reagent for Hemoglobin test
Parameters
27: WBC, Lym%, Mon%, Neu%, Eos%, Bas%, Lym#, Mon#, Neu#, Eos#,
Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT,
MPV, PDW, PCT, LIC%, LIC#, ALY%, ALY#
3 histograms and 1 scattergram
Throughput
Up to 60 samples per hour
Sample Volume
Whole Blood: 20 μL
Prediluted: 20 μL
Test Mode
CBC CBC+DIFF
Performance
Carryover Precision Linearity
WBC ≤ 0.5% ≤ 2.0% (4-15 x 10?/L) 0.00-99.99 x10?/L
RBC ≤ 0.5% ≤ 1.5% (3.5-6.0 x 10¹²/L) 0.00-8.00 x10¹²/L
HGB ≤ 0.5% ≤ 1.5% (110-180g/L) 0-250g/L
PLT ≤ 1.0% ≤ 4.0% (150-500 x 10?/L) 0-1000 x10?/L
Data Storage Capacity
Up to 40,000 results including numeric and graphical information
Communication
LAN Port supports HL7 protocol
Operating Environment
Temperature: 15°C~30°C
Humidity: 30~85%
Air Pressure: 70~106 kPa
Power Requirement
A.C 100-240V ≤ 300VA 50/60Hz
Dimension and Weight
410mm(L) x 470mm(W) x 530mm(H)
Weight: ≤45 Kg
The new BC-5300 Auto Hematology Analyzer is a bench top system, combining three mainstream technologies: laser scatter, flow cytometry and chemical dye to provide reliable and accurate 5-part differentiation on white blood cells. Tailored for independent labs, BC-5300 is compact, economical and very friendly to use. Only 20uL of blood is enough to have a 27-parameter report within 1 minute. The software also provides arrays of advanced features to enhance lab efficiency, for example, customization on reference range and report formats, patient historical check, workload statistics and LIS connection. BC-5300 requires zero daily maintenance and is equipped with automatic cleaning set-up to make your daily use as comfortable as possible. Semi-conductor laser scatter combined with chemical dye method and advanced flow cytometry 27 parameters for complete 5-part differentiation (CBC+DIFF) on white blood cells including immature cells Compact and no external air pump to avoid noise 20 µL blood sampling for CBC+DIFF test while 15uL for CBC test Up to 60 samples per hour throughput Supports both whole blood and capillary blood samples Windows software with at least 40,000 storage for patient results and 60 files for QC data Customization on reference range, auto-cleaning schedule and report format Support bi-directional LIS connection
White blood cell differentiation The semi-conductor laser system collects forward scatter and side scatter information of white blood cells in a flow cell and differentiates lymphocytes, monocytes, neutrophils and eosinophils according to the cell size and granule complexity. Specific chemical dye treatment to eosinophils can separate from neutrophils in DIFF scattergram. In addition, basophils are measured in an impedance channel upon lysing action on the RBC and other WBC groups.
Advanced impedance measurement for RBC and PLT Mindray patented digital sheath flow and weak signal detection techniques are applied to ensure accurate counting and sizing of RBC and PLT in the impedance channel. Dynamic discriminator adjustment can improve the separation of RBC and PLT groups when large platelet and micro RBC are present. Benefiting from these improvements, MCV, RDW and PLT performance are greatly enhanced.
Flag abnormity
Besides of the routine CBC+DIFF results, BC-5300 offers data result for large immature cell and atypical lymphocytes in infectious diseases. Intelligent flagging system can help doctors fish out suspicious cases for further validation check. For example, microcytosis, anemia, eosinophilia, PLT clump and so on. The manual microscopic check results and morphology description can be print together in the final report.