Description
Quick Details
The product is mainly used for blending of the syphilis test card, colloid reaction and complement fixation reaction. It is can also be used for blending in clinical tests and other biochemical tests.
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
High quality Oscillator MSL-OS02
MSL High quality Oscillator MSL-OS02 Profile
The product is mainly used for blending of the syphilis test card, colloid reaction and
complement fixation reaction. It is can also be used for blending in clinical tests and other biochemical tests.
The product is stable, reliable and operator friendly, which is a requisite instrument for
tests in all kinds of hospitals, institutions, centers of prevention and cure of STD??
sanitation and anti-epidemic stations, blood stations.
Technical Parameters
Voltage?? AC 220V 50/60Hz
Power?? 15W
Rotation Speed?? 0-210 r/min. adjustable
Timing?? 0??24 hours adjustable??count down mode
“0” is normally running mode
?? Over-center Rotation Diameter?? 22mm
Dimension of Working Table?? 384×248(mm)
Fuse?? 2A
Operation
1??When it is connected to the power and is switched on, we hear the bumming sound,
the function indication lights is on and the relative parameters are shown on instrument.
2??Press the “Rotation Speed” key (the correspondent
indication light is on). Adjust the “Rotate” key, “10 Rotates” key or “100 Rotates” key to
adjust the set-value. After finish these, press the “Enter” Key to store the set-value.
If adjustment is unnecessary, skip this step. (Note: The adjust range of “Rotate” key
is 0-9,“10 Rotates” key is 0-4 while “100 Rotates” key is 0-2 ).
3. Press the “Timing” key (the correspondent indication light is on). Adjust the set-values
by “Minute” key and “10 Minutes” key as well as “Hour” key. After finishing this, press the
“Enter” key to store the set-value. If adjustment is unnecessary, skip this step. (Note:
The adjust range of “Minute” key is 0-9, “10 Minutes” key is 0-5 while “Hour” key is 0-23).
4??After set the parameters, press “Start/Pause” key to start the instrument. You may press the
“Start/Pause” key again to pause the instrument while the timing is also stops. When start again,
timing continues. It can be done repeatedly. You can check all the parameters by pressing
different keys during machine running, but the values can’t be adjusted. After pause the instrument,
the value can be adjusted. The instrument returns to timing indication mode after 60 seconds stop.
5.The instrument is bumming for alarm after timing is finished, while the time shows “00??00”.
You may press the “Start/Pause” key directly to start the instrument if the value adjustment is
unnecessary. The instrument shows the set-value if paused for more than 60 seconds.
6. Turn off the instrument when the operation is finished.
Precautions
1.AC power should be well connected to the ground and its voltage should be within the regulated scope.
2. The instrument should be put on a proper place on the working station. Avoid heavy press.
3. Avoid long time unloaded running and cut off the power when it is not in use.
4. Never open the shell to avoid electric shock. Find special person for maintenance.
MSL factory picture??medical supplier for Long-term cooperation.
MSL TEAM picture
MSL Certificate
MSL Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods? arrive destination safely and quickly.
Welcome to medicalequipment-msl.com,If you have any demand in Oscillator. Please feel free to
contact cindy@medicalequipment-msl.com
There are no reviews yet.