Description
Quick Details
PCV and SIMV+PS modes ensure flexibility in ventilation, machine doable for both pediatric and adult operation
Optional monitoring functions, CO2 and anesthetic gas
Flowmeter provides minimum 25% concentration of oxygen in O2 /N2O mixture
Breathing system easy to remove and clean, fully autoclavable, optional CO2 bypass
Enhances usability with auxiliary oxygen, suction, auxiliary power source, monitor arm, infusion pump etc.
CE marked, meets EU clinical requirement
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
Anesthesia System Machine MSLGA30 With Precise Control And Easy Operation
- PCV and SIMV+PS modes ensure flexibility in ventilation, machine doable for both pediatric and adult operation
- Optional monitoring functions, CO2 and anesthetic gas
- Flowmeter provides minimum 25% concentration of oxygen in O2 /N2O mixture
- Breathing system easy to remove and clean, fully autoclavable, optional CO2 bypass
- Enhances usability with auxiliary oxygen, suction, auxiliary power source, monitor arm, infusion pump etc.
- CE marked, meets EU clinical requirement
Anesthesia System Machine MSLGA30 Physical & Environment Specifications:
·Dimensions(W×H×D): 704mm × 1403mm × 750mm (without YOKE)
·Weight: 100kg (basic unit)
·Operation Temperature: +10~+40°C
·Operation Humidity: ≤80% (noncondensing)
·Storage Temperature: -20~+60°C
·Storage Humidity: ≤95% (noncondensing)
·Electrical Specifications
·Mains: 100~240V AC, 50/60Hz
·Battery: 24V 4Ah, minimum 120 min
·Outlets: 3 on back, 1.5A individual
·Pneumatic Specifications
·Gas Supply: Air, O2, N2O; 280kPa ~ 600kPa
·Flowmeters: O2 Range: 0~1L/min; 1~10L/min
·N2O Range: 0~1L/min; 1~10L/min
·Air Range: 0~1L/min; 1~12L/min
·Auxiliary O2 Range: 0 ~12L/min
·Flowmeter backlight
·Gas System: Oxygen supply failure alarm
·Oxygen supply failure protection
·O2 flush: 25~75L/min
·ACGO: Optional auxiliary common gas outlet
·AGSS: Optional anesthetic gas scavenging system
Anesthesia System Machine MSLGA30 Breathing System Specifications:
·Operational Modes: Closed, Semi-closed, Semi-open
·CO2 Canister: 2 Loose fill (3L) or 2 prepacks, optional single canister
·APL Range: Spontaneous breathing (SP) -70 cmH2O
·Material: Autoclavable (except O2 cell and mechanical pressure gauge)
·Heating system: Optional
·CO2 bypass: Optional
·Ventilator Specifications
·Driven Mode: Pneumatically driven and electronically controlled
·Patient Types: Adult and Pediatric populations weighing above 2kg
·Ventilation Modes: IPPV, PCV, SIMV+PS, PS and Manual
·Setting Modes: Touch key & navigator wheel knob
·Tidal Volume: 20~1500ml
·Ventilation Frequency: 4~100bpm
·I:E Ratio: 4:1~1:8
·Pressure (inspired) Range: 5~70cmH2O
·Pressure (support) Range: 3~50cmH2O
·PEEP: Off, 3~30 cmH2O
·Tslope: 0~2s
·Inspiratory Plateau: Off, 5%~60%Ti
·Trigger Sensitivity: 1~15L/min
·Compensation: Compliance and leakage compensation, fresh gas compensation, altitude compensation
Anesthesia System Machine MSLGA30 Ventilator Specifications:
·Display: 10.4" TFT color screen
·Pressure: Paw, Ppeak, Pplat, Pmean, PEEP
·Volumes: MV, Vt, Freq
·Gas: FiO2, optional: CO2, AG, MAC
·Graph Display: P-t, F-t, P-V, F-V and optional CO2 -t
·Alarm: High Airway Pressure/Low Airway Pressure
·Sustained airway pressure
·High Minute Volume/Low Minute Volume
·High FiO2/Low FiO2
·High Breath Rate
·O2 Supply failure
·Power failure
·Apnea Alarm
·Alarm Silence: 110 seconds
·Vaporizer
·Support two vaporizers
·Agent: Halothane, Enflurane, Isoflurane, Sevoflurane
·Installation Mode: Selectatec with interlock, optional standby vaporizer parking holder
·Filling Type: Pour Fill, Key Fill, Quik-Fil
There are no reviews yet.