The comprehensive ventilation modes including PCV-VG??SIMV-PC provide more flexibility to ventilation strategy, suitable for various patients operation including pediatric and adult
Advanced ventilation management, provides a accurate and broad of settings enabling effective care across a wide range of patient sizes and acuity types
Support both low-flow anesthesia and mini-flow anesthesia
Compact breathing system, easy to remove and clean, fully autoclavable, optional CO2 bypass
Electronic flow-meter, precise control and convenient operation
12.1" TFT LCD with color touch screen, highlighted display
Optional comprehensive gas monitoring include: oxygen (paramagnetic), CO2, AG, etc.
CE marked, meets EU clinical requirement
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
Anesthesia System Machine MSLGA28 With Precise Control And Easy Operation
- The comprehensive ventilation modes including PCV-VG??SIMV-PC provide more flexibility to ventilation strategy, suitable for various patients operation including pediatric and adult
- Advanced ventilation management, provides a accurate and broad of settings enabling effective care across a wide range of patient sizes and acuity types
- Support both low-flow anesthesia and mini-flow anesthesia
- Compact breathing system, easy to remove and clean, fully autoclavable, optional CO2 bypass
- Electronic flow-meter, precise control and convenient operation
- 12.1" TFT LCD with color touch screen, highlighted display
- Optional comprehensive gas monitoring include: oxygen (paramagnetic), CO2, AG, etc.
- CE marked, meets EU clinical requirement
Anesthesia System Machine MSLGA28 Base Unit:
·Dimensions (H x W x D)
·Trolley version (with breathing circuit): 1403mm×704mm×750mm or 55.2in×27.7in×29.5in
·Weight and load
·Trolley (without vaporizer and backup cylinder): 100kg or 220.5 lb
·Top shelf load: 25kg or 55 lb
·Power and battery backup
·Power input 100~240 VAC, 50/60 Hz
·Batteries and Operation time with fully charged: DC24V, 4.0AH, Min.120minutes
·Environmental requirement
·Operation temperature: 10~+40?? or 50~104?H
·Operation humidity: ≤80%(non-condensing)
·Storage temperature: -20~+60?? or -4~131?H
·Storage humidity: ≤95%(non-condensing)
Anesthesia System Machine MSLGA28 Anesthesia Gas Supply Module:
·Gas supply: O2, N2O, AIR; 280kPa – 600kPa
·Cylinder yokes Optional: O2, N2O, AIR
·Fresh gas ow indicator: Electronically display and virtual fresh gas ow tubes
·Range of fresh gas ow indicators: O2, N2O (0.05~10.0 l/min), AIR (0.05~12.0 l/min)
·O2 flush: 25~75 l/min
·Vaporizer
·Auxiliary common gas outlet (ACGO): Optional
·Anesthetic Gas Scavenging System (AGSS): Optional
·Agent: Halothane, Enurane, Isourane , Sevourane
·Installation mode: Selectatec® with interlock, optional standby vaporizer parking holder
·Filling type: Pour Fill, Key Fill, Quik-Fil
·Breathing system
·Volume of CO2 absorber: 3 L for double-canister or 1.8 L for optional single canister
Anesthesia System Machine MSLGA28Ventilator Operating Specifications:
·APL Range: Spontaneous breathing (SP) -70cm H2O
·Material: Autoclavable (except O2 cell and mechanical pressure gauge)
·Heating system: 32-40??
·CO2 bypass: Optional
·Ventilator: Electronically controlled, pneumatically driven
·Ventilation modes: Manual/spontaneous, Volume control (IPPV), Pressure control (PCV), Pressure Controlled Ventilation Volume Guaranteed??PCV-VG), Synchronized Intermittent Mandatory ·Ventilation in volume(SIMV-VC), Synchronized Intermittent Mandatory Ventilation in pressure(SIMV-PC), Pressure support (PS) with Apnea backup
·Control input ranges
·Breathing frequency (rate): 2~100bpm
·Positive end expiratory pressure (PEEP): OFF, 3~30cm H2O
·Inspiration/expiration ratio (Ti:Te): 4:1~1:8
·Tidal volume (Vt): 20~1,500ml in volume control
·Inspiration pause: OFF, 5%~60%
·Inspiratory time: 0.2~5.0 s
·Inspiratory pressure(PTARGET): 5~70cm H2O
·Pressure support level (ΔP): 3~50cm H2O
·Pressure limit (Pmax): 10~70 cm H2O
·Trigger level: 1~15 l/min
·Inspiratory Slope Time (TSLOPE): 0~2s
·Compensation: Compliance and Leak compensation, fresh gas compensation, altitude compensation
·Ventilator monitoring & alarm
·Monitoring: Continuous monitoring of inspiratory O2 concentration, breathing frequency, tidal, volume, minute volume, peak airway pressure, PEEP, mean or plateau pressure, CO2 concentration (optional), anesthetic gas concentration (optional), paramagnetic oxygen sensors (optional)
·Compliance: 0~100 mL/cm H2O
·Control screen: 12.1 in; TFT color touch screen
·Graph Display: Waveform of P-t, F-t, V-t, CO2-t (option), Paw-V Loop, V-Flow Loop
·Alarm:
MV high/low limit, FiO2 high/low limit, Paw high/low limit, Power failure
Breath Rate high limit
Subatmospheric pressure
Sustained airway pressure
Apnea alarm, Alarm Silence(120s)