Description
Quick Details
1.AED
2.Two-button operation, lock-out protection
3.Biphasic energy output
4.External voice and visual prompt
5.CE, ISO13485
Automatic External Defibrillators
defibrillator for the heart
automatic external defibrillator cost
automatic external defibrillator manufacturer
automated external defibrillator
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
Automatic External Defibrillator Brief Introduction:
AED7000 is a portable model, which can be equipped at home, in public places, or in the hospitals. It’s easy and convenient to use when give first-aid to patient. Meanwhile, it has the function of automatic analyzing patient’s ECG data, and then takes corresponding defibrillation energy level according to patient’s current situation, which has greatly improved success rate, and maximum reduced damage to patient’s heart.
Automatic External Defibrillator Features:
1. Three-step defibrillation process
2. Two-button operation
3. Extensive voice and visual prompts for the operator
4. Biphasic energy output
5. Lock-out protection to prevent inadvertent defibrillation
6. Continuous event recording for reporting each use to a printer or computer
7. Weekly self-test to ensure readiness
Automated external defibrillator | AED Specification:
Defibrillator
Output Biphasic Truncated Exponential
Energy Sequence 150, 150, 200J
Charge Time 8 sec. to 150J; 10 sec. to 200J (New Battery)
Analysis Time 9 sec.
The maximum time from the initiation of rhythm analysis to readiness for discharge with a new battery
Less than 30 seconds
The maximum time from the initiation of rhythm analysis to readiness for discharge after 6 shocks Less than 35 seconds
The maximum time from initially switching power on to readiness for discharge Less than 25 seconds
Audible Prompts 22 audible prompts
Visual Prompts LED prompts
Controls Two buttons-ON/Off, Shock
Output Energy Accuracy ±15% into any impedance from 25 to 175Ω
The Maximum Voltage 1200±50V
Output disabled when the patient impedance is outside limits 20Ωto 200Ω
Automated external defibrillator Battery
Part No. CR123A-4*2
Non-rechargeable 12V DC, 2.8Ah
Capacity At 150 Joules
Automated external defibrillator Physical
Dimensions 303*216*89mm
Weight 2.0kg
Operating Temperature 0°C to 40°C
Automated external defibrillator Operating Humidity Relative humidity between 30% and 95% (non-condensing)
Storage Temperature (without battery) -20°C to 55°C
Storage Humidity (without battery) Up to 95% (non-condensing)
There are no reviews yet.