Description
Quick Details
Assay methods: End Point, Kinetic, Fix time etc.
Principle: Photoelectric colorimetry
Light Source: Halogen lamp 12V/20W
Photometry range: 0~3.2Abs
Resolution: 0.0001Abs
Wavelength: 340nm405nm450nm492nm510nm546nm578nm630nm700nm800nm
Throughput: 200 tests/hour
Reagent tray: 60 reagent positions (include1detergent position,1 dilution position)
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
24 hour non-stop cooling Chemistry Analyzer machine URIT-8021A
Random access, 200 tests per hour
Durable ceramic syringes
Select best test point by reaction curve, create
new factor automatically
Support bi-direction LIS and HIS interface
Durable ceramic syringes Chemistry Analyzer machine URIT-8021A Features
24 hour non-stop cooling system to ensure reagent at 2-8??
Durable ceramic syringes to ensure accuracy & precision
High accurate optical system
Collision protection in both vertical and horizontal directions, stop & alarm automatically
once touching barrier, not affect former tests
Automatic eligible cuvettes detection & selection
Select best test point by reaction curve, create new factor automatically
Support LIS interface
Automatic eligible cuvettes detection Chemistry Analyzer machine URIT-8021A Specifications
Assay methods: End Point, Kinetic, Fix time etc.
Principle: Photoelectric colorimetry
Light Source: Halogen lamp 12V/20W
Photometry range: 0~3.2Abs
Resolution: 0.0001Abs
Wavelength: 340nm405nm450nm492nm510nm546nm578nm630nm700nm800nm
Throughput: 200 tests/hour
Reagent tray: 60 reagent positions (include1detergent position,1 dilution position)
Sample tray: 71 sample positions, including detergent, standard, QC, STAT positions
Reaction tray: 120 reaction cuvettes
Sample volume: 2~100ul, with 0.1ul increment
Reagent volume: R1:10~500uL, R2: 10~500uL,with 0.5uL increment
Minimum reaction volume: 180uL
Maximum reaction time: 10 minutes
Water Consumption: Less than 5L/hour under working status
Clean unit: 8-step auto-washing system with detergent
Calibration: Calibration reset, select best test point by reaction curve, no need second calibration
Line/non-line;multi-standards assay
Control rules: Westgard multi-rule, Cumulative sum check, Twin plot
3 level controls for each ifem, analyxing and printing QC analysis diagram
Temperature control: incubator 37±0.1??
Power supply: AC 230(1±10%)V, 50/60Hz, 500VA
Ambient: Operating temperature: 10~30??
Relative humidity: ≤85%
Atmospheric pressure: 86~106kPa
High performance mixer design
Absence of cross contamination
Optimal homogenization in minimum time
Mixing immediately after dispensing of sample and the second reagent
Stable Optical System
High accurate, close, static state optical system
Spot photometry with high speed digital transmission system
Durable cuvettes
8-step auto-washing system with detergent and deion-water to ensure
cuvettes clean and decrease cross contamination
120 reaction cuvettes located in a constant temperature incubator
Low consumption, open reagent design