Ecg machine > Portable ekg/ecg machine

Advanced design Dynamic ECG System EKONHT01

MODEL / EKONHT01

Advanced design Dynamic ECG System EKONHT01. The recorder can real-time store ECG data for 24-hour.

  • The recorder can real-time store ECG data for 24-hour.
  • Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.
  • Sync analysis for 12-lead, which ensures that QRS waveform can be found accurately, and no distortion.
  • EKON 12-lead ECG System EKONHT01 Function
PRODUCT OVERVIEW

Product Details

Quick Details

The recorder can real-time store ECG data for 24-hour.

Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.

Sync analysis for 12-lead, which ensures that QRS waveform can be found accurately, and no distortion.

Specifications

Advanced design Dynamic ECG System EKONHT01

12-lead ECG System EKONHT01

Introduction

Dynamic ECG Systems adopt 12-lead system of international standard,

which can continuously record ECG waveform for 24-hour and analyze

ECG waveform by the PC software. It is applicable for use in medical institution and community.

design Dynamic 12-lead ECG System EKONHT01

MSL 12-lead ECG System EKONHT01 Function

1) The recorder can real-time store ECG data for 24-hour.

2) Arrhythmia analysis basing on MCSSTM and TMCATM can

greatly reduce doctor’s work.

3) Sync analysis for 12-lead, which ensures that QRS waveform can be

found accurately, and no distortion.

4) With more than 10 templates(such as atrial premature beat, ventricular

premature beat, long interval, atrial fibrillation, etc.) and many user-defined

modules, which can almost distinguish any kind of pathologic waveforms.

5) Flexible analysis channel selection function, which ensures that any

channels can be selected as the main analysis channel.

6) Flexible atrial fibrillation analysis, which ensures that physicians can

use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.

7) All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful

pacemaker analysis function.

8) With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”,

“Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.

9) Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis

function. 10)With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.

11)One-key print, convenient and fast to print the reports. 12)Perfect case management function.

13) Abnormal ST can be analyzed according to the whole and event by the advanced ST

segment analysis and total load of myocardial ischemia, which can help the doctors

comprehensively judge myocardial ischemia.

14) The risk of sleep breath pause can be predicted by the unique "Sleep breath

pause syndrome"analysis function.

15) The death risk in patients with myocardial infarction can be predicted by the "HRT"

analysis function. 16)“T-Wave alternation” is an important index to predict the malignant

arrhythmia and sudden cardiac death.

17)With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential)

and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.

Advanced design Dynamic 12-lead ECG EKONHT01

Portable 12-lead ECG System EKONHT01 Performance

Lead: standard 12-lead Record time: 24-hour

Power supply: two “AA” batteries Interface: USB2.0

Calibration voltage: 1mV±5% Noise level: ≤30μV

CMRR: ≥60dB

Low-frequency characteristics: time constant≥3.2s Scan speed: 25mm/s±5%

Polarizing voltage: ±300mV, sensitivity: ≤±10% Minimum measure signal: 50 µV p-p

MSL 12-lead ECG System EKONHT01

Cheap 12-lead ECG System EKONHT01 Accessories

Lead cable (1 set) ECG electrode (1 bag) USB cable(1)

Disk(1) Bag(1)

User manual(1)

Portable 12-lead ECG System EKONHT01

Physical characteristic

Dimension: 111mm(L) × 60mm(W) × 25mm(H) Weight: about 105g(without batteries)

Cheap 12-lead ECG System EKONHT01
TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Lead
standard 12-lead Record time: 24-hour
Power supply
two “AA” batteries Interface: USB2.0
Calibration voltage
1mV±5% Noise level: ≤30μV
CMRR
≥60dB
Low-frequency characteristics
time constant≥3.2s Scan speed: 25mm/s±5%
Polarizing voltage
±300mV, sensitivity: ≤±10% Minimum measure signal: 50 µV p-p
Dimension
111mm(L) × 60mm(W) × 25mm(H) Weight: about 105g(without batteries)

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us