MODEL / EKONGA28

The comprehensive ventilation modes including PCV-VG,SIMV-PC provide more flexibility to ventilation strategy, suitable for various patients operation including pediatric and adult

  • Support both low-flow anesthesia and mini-flow anesthesia
  • Compact breathing system, easy to remove and clean, fully autoclavable, optional CO2 bypass
  • 1" TFT LCD with color touch screen, highlighted display
  • CE marked, meets EU clinical requirement
PRODUCT OVERVIEW

Product Details

Quick Details

The comprehensive ventilation modes including PCV-VG,SIMV-PC provide more flexibility to ventilation strategy, suitable for various patients operation including pediatric and adult

Advanced ventilation management, provides a accurate and broad of settings enabling effective care across a wide range of patient sizes and acuity types

Support both low-flow anesthesia and mini-flow anesthesia

Compact breathing system, easy to remove and clean, fully autoclavable, optional CO2 bypass

Electronic flow-meter, precise control and convenient operation

12.1" TFT LCD with color touch screen, highlighted display

Optional comprehensive gas monitoring include: oxygen (paramagnetic), CO2, AG, etc.

CE marked, meets EU clinical requirement

Specifications

Anesthesia System Machine EKONGA28 With Precise Control And Easy Operation

  • The comprehensive ventilation modes including PCV-VG,SIMV-PC provide more flexibility to ventilation strategy, suitable for various patients operation including pediatric and adult
  • Advanced ventilation management, provides a accurate and broad of settings enabling effective care across a wide range of patient sizes and acuity types
  • Support both low-flow anesthesia and mini-flow anesthesia
  • Compact breathing system, easy to remove and clean, fully autoclavable, optional CO2 bypass
  • Electronic flow-meter, precise control and convenient operation
  • 12.1" TFT LCD with color touch screen, highlighted display
  • Optional comprehensive gas monitoring include: oxygen (paramagnetic), CO2, AG, etc.
  • CE marked, meets EU clinical requirement
Anesthesia system machine EKONGA28 for sale | Medsinglong

Anesthesia System Machine EKONGA28 Base Unit:

·Dimensions (H x W x D) ·Trolley version (with breathing circuit): 1403mm×704mm×750mm or 55.2in×27.7in×29.5in ·Weight and load ·Trolley (without vaporizer and backup cylinder): 100kg or 220.5 lb ·Top shelf load: 25kg or 55 lb ·Power and battery backup ·Power input 100~240 VAC, 50/60 Hz ·Batteries and Operation time with fully charged: DC24V, 4.0AH, Min.120minutes ·Environmental requirement ·Operation temperature: 10~+40℃ or 50~104℉ ·Operation humidity: ≤80%(non-condensing) ·Storage temperature: -20~+60℃ or -4~131℉ ·Storage humidity: ≤95%(non-condensing)

Anesthesia system machine EKONGA28 for sale | Medsinglong

Anesthesia System Machine EKONGA28 Anesthesia Gas Supply Module:

·Gas supply: O2, N2O, AIR; 280kPa - 600kPa ·Cylinder yokes Optional: O2, N2O, AIR ·Fresh gas ow indicator: Electronically display and virtual fresh gas ow tubes ·Range of fresh gas ow indicators: O2, N2O (0.05~10.0 l/min), AIR (0.05~12.0 l/min) ·O2 fl ush: 25~75 l/min ·Vaporizer ·Auxiliary common gas outlet (ACGO): Optional ·Anesthetic Gas Scavenging System (AGSS): Optional ·Agent: Halothane, En urane, Iso urane, Sevo urane ·Installation mode: Selectatec® with interlock, optional standby vaporizer parking holder ·Filling type: Pour Fill, Key Fill, Quik-Fil ·Breathing system ·Volume of CO2 absorber: 3 L for double-canister or 1.8 L for optional single canister

Anesthesia system machine EKONGA28 for sale | Medsinglong

Anesthesia System Machine EKONGA28Ventilator Operating Specifications:

·APL Range: Spontaneous breathing (SP) -70cm H2O ·Material: Autoclavable (except O2 cell and mechanical pressure gauge) ·Heating system: 32-40℃ ·CO2 bypass: Optional ·Ventilator: Electronically controlled, pneumatically driven ·Ventilation modes: Manual/spontaneous, Volume control (IPPV), Pressure control (PCV), Pressure Controlled Ventilation Volume Guaranteed(PCV-VG), Synchronized Intermittent Mandatory ·Ventilation in volume(SIMV-VC), Synchronized Intermittent Mandatory Ventilation in pressure(SIMV-PC), Pressure support (PS) with Apnea backup ·Control input ranges ·Breathing frequency (rate): 2~100bpm ·Positive end expiratory pressure (PEEP): OFF, 3~30cm H2O ·Inspiration/expiration ratio (Ti:Te): 4:1~1:8 ·Tidal volume (Vt): 20~1,500ml in volume control ·Inspiration pause: OFF, 5%~60% ·Inspiratory time: 0.2~5.0 s ·Inspiratory pressure(PTARGET): 5~70cm H2O ·Pressure support level (ΔP): 3~50cm H2O ·Pressure limit (Pmax): 10~70 cm H2O ·Trigger level: 1~15 l/min ·Inspiratory Slope Time (TSLOPE): 0~2s ·Compensation: Compliance and Leak compensation, fresh gas compensation, altitude compensation ·Ventilator monitoring & alarm ·Monitoring: Continuous monitoring of inspiratory O2 concentration, breathing frequency, tidal, volume, minute volume, peak airway pressure, PEEP, mean or plateau pressure, CO2 concentration (optional), anesthetic gas concentration (optional), paramagnetic oxygen sensors (optional) ·Compliance: 0~100 mL/cm H2O ·Control screen: 12.1 in; TFT color touch screen ·Graph Display: Waveform of P-t, F-t, V-t, CO2-t (option), Paw-V Loop, V-Flow Loop ·Alarm: MV high/low limit, FiO2 high/low limit, Paw high/low limit, Power failure Breath Rate high limit Subatmospheric pressure Sustained airway pressure Apnea alarm, Alarm Silence(120s)

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

·APL Range
Spontaneous breathing (SP) -70cm H2O
·Material
Autoclavable (except O2 cell and mechanical pressure gauge)
·Heating system
32-40℃
·Ventilator
Electronically controlled, pneumatically driven
·Ventilation modes
Manual/spontaneous, Volume control (IPPV), Pressure control (PCV), Pressure Controlled Ventilation Volume Guaranteed(PCV-VG), Synchronized Intermittent Mandatory ·Ventilation in volume(SIMV-VC), Synchronized Intermittent Mandatory Ventilation in pressure(SIMV-PC), Pressure support (PS) with Apnea backup
·Breathing frequency (rate)
2~100bpm
·Positive end expiratory pressure (PEEP)
OFF, 3~30cm H2O
·Inspiration/expiration ratio (Ti
Te): 4:1~1:8
·Tidal volume (Vt)
20~1,500ml in volume control
·Inspiration pause
OFF, 5%~60%
·Inspiratory time
0.2~5.0 s
·Inspiratory pressure(PTARGET)
5~70cm H2O
·Pressure support level (ΔP)
3~50cm H2O
·Pressure limit (Pmax)
10~70 cm H2O
·Trigger level
1~15 l/min
·Inspiratory Slope Time (TSLOPE)
0~2s
·Compensation
Compliance and Leak compensation, fresh gas compensation, altitude compensation
·Monitoring
Continuous monitoring of inspiratory O2 concentration, breathing frequency, tidal, volume, minute volume, peak airway pressure, PEEP, mean or plateau pressure, CO2 concentration (optional), anesthetic gas concentration (optional), paramagnetic oxygen sensors (optional)
·Compliance
0~100 mL/cm H2O
·Control screen
12.1 in; TFT color touch screen
·Graph Display
Waveform of P-t, F-t, V-t, CO2-t (option), Paw-V Loop, V-Flow Loop
MV high/low limit, FiO2 high/low limit, Paw high/low limit, Power failure
Breath Rate high limit
Sustained airway pressure
Apnea alarm, Alarm Silence(120s)

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.