Auto digital multi-function CRP machine EKONHS03 for sale
MODEL / EKONHS03Auto digital multi-function CRP machine EKONHS03 for sale. produce and other rescue measures. .
- 8、with a separate continuous ventilation function, ventilation frequency 8-16times/minute continuously adjustable
- 9、Electricity, according to the low voltage alarm, start the suspended function
- 10、The pressure is not enough to alarm, the pressure depth is reduced automatically, and the manual recovery after air pressure recovery must be deep.
- 11、Pressure depth of 50MM and above to confirm function
Product Details
Quick Details
Air access equipped with Fast plug-in; Quick start in 2 scconds; Fuselage rotate 360 degrees,it's convenient to cooperate to produce and other rescue measures..
Specifications
1. Working environment
Temperature: 1 0℃ ~ 40℃ Relative temperature: 30% ~ 75% Atmospheric pressure: 700hPa ~ 1060hPa; Power supply voltage: AC 220V ± 22V, 50Hz ± 1Hz; DC 12.6V ± IV Air supply pressure: 0.35MPa ~ 0.6Mpa

2、input power:DC:≤17W;AC:≤54W; 3、 Ventilation quanity: 350ml~900ml continuously adjustable 4、Pressing depth: 30mm~70mm continuously adjustable, each adjustment 5mm; 5、Pressing frequency: 80 times/minute, 90 times/minute, 100 times/minute, 110 times/minute, 120 times/minute continuously adjustable; 6、Press the ventilation ratio: 30: 2,15: 2, separete continuously press three operation modes can be switched; 8、with a separate continuous ventilation function, ventilation frequency 8-16times/minute continuously adjustable; 9、Electricity, according to the low voltage alarm, start the suspended function; 10、The pressure is not enough to alarm, the pressure depth is reduced automatically, and the manual recovery after air pressure recovery must be deep.

11、Pressure depth of 50MM and above to confirm function 12、Default mode:Press the ventilation ratio: 30: 2,press depth 30mm,press frequence 100 pcs/min;Ventilation quanity 350ML 13、vertical adjustment height: minimum 155mm, maxium 315mm; 14、outsize:the main machine size:L×W×H=660 ㎜×566 ㎜×(526.5~686.5)㎜ resuscitation plate size:L×W×H=485 ㎜×460 ㎜×56mm 15、Safety requirements refer to medical electrical appliances safety standard GB 9706.1-2007, electromagnetic compatibility standard YY05052012
Technical Specifications
Technical parameters from the currently available product information.
- Temperature
- 1 0℃ ~ 40℃
- Relative temperature
- 30% ~ 75%
- Atmospheric pressure
- 700hPa ~ 1060hPa
- Power supply voltage
- AC 220V ± 22V, 50Hz ± 1Hz; DC 12.6V ± IV
- Air supply pressure
- 0.35MPa ~ 0.6Mpa
- 、input power
- DC:≤17W;AC:≤54W;
- 、 Ventilation quanity
- 350ml~900ml continuously adjustable
- 、Pressing depth
- 30mm~70mm continuously adjustable, each adjustment 5mm
- 、Pressing frequency
- 80 times/minute, 90 times/minute, 100 times/minute, 110 times/minute, 120 times/minute continuously adjustable
- 、Press the ventilation ratio
- 30: 2,15: 2, separete continuously press three operation modes can be switched
- 、Pressure depth of
- 50MM and above to confirm function
- 、Default mode
- Press the ventilation ratio: 30: 2,press depth 30mm,press frequence 100 pcs/min;Ventilation quanity 350ML
- 、vertical adjustment height
- minimum 155mm, maxium 315mm
- 、outsize
- the main machine size:L×W×H=660 ㎜×566 ㎜×(526.5~686.5)㎜
- resuscitation plate size
- L×W×H=485 ㎜×460 ㎜×56mm
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.