Automated blood coagulation analyzer RAC-1800 for sale. Clotting Method: PT, APTT, TT, FIB, etc.

  • 一Automatic, Random Access
  • 一Clotting, Chromogenic, Immunologic measuring methods
  • 一188 tests/hour for PT
  • 一86 tests/hour for D-Dimer
PRODUCT OVERVIEW

Product Details

Quick Details

一Automatic, Random Access

一Clotting, Chromogenic, Immunologic measuring methods

一188 tests/hour for PT

一86 tests/hour for D-Dimer

Specifications

Automated coagulation analyzer RAC-1800

Automated coagulation analyzer RAC-1800 Features

一Automatic, Random Access

一Clotting, Chromogenic, Immunologic measuring methods

一188 tests/hour for PT

一86 tests/hour for D-Dimer

一Autoloader for cuvettes

一User-friendly operation software

一Bi-directional LIS system

一 STAT sample priority

一Reagent open system, close system on request

一Barcode-reading for sample and reagent (Optional)

coagulation analyzer RAC-1800

Automated coagulation analyzer RAC-1800 Technical Specifications

System Function

.Throughput: 188 tests/hour for PT

86 tests/hour for D-Dimer

.Measuring methods and parameters:

Clotting Method: PT, APTT, TT, FIB, etc.

Chromogenic Method: AT-iii, PLG, a2-AP, PC,

Heparin, etc.

Immunologic Method: D-Dimer, FDP, etc.

Sample Tray

.Sample tray: 55 positions

user一efined STAT

Reagent Tray

.Reagent tray: 24 positions with cooling怕nction

5 positions without cooling function

.Reagent cooling: <16℃

Reaction Tray

.Cuvettes on board:300

.Min reaction volume: 150u1

.Incubators positions: 18

.Reaction temperature: 3710.50C

Automated coagulation analyzer RAC-1800 Probe

.1 reagent probe and I sample probe:

with collision protection, liquid level detection

and inventory checking function.

.Reagent probe: with reagent preheating,

and overheating protection function.

Print out

.External PC controlled printer

Others

.Power: AC 110V/220V, 50-6011 Hz

.Water consumption: 6Uhour

.Dimension LxW二H (mm):820x680x550

.Weight: 100Kg

Automated coagulation analyzer RAC-1800 Optical System

.LED light

.8 clotting detection channels,

660nm

.5 transmission detection channels,

(for both Chromogenic assays

and Immunologic assays),

4 standard wavelengths:

405nm, 575nm, 660nm, 800nm,

2 more optional

(from 400nm-900nm)

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

.Throughput
188 tests/hour for PT
Chromogenic Method
AT-iii, PLG, a2-AP, PC
.Sample tray
55 positions
.Reagent tray
24 positions with cooling怕nction
.Reagent cooling
<16℃
.Cuvettes on board
300
.Min reaction volume
150u1
.Incubators positions
18
.Reaction temperature
3710.50C
.1 reagent probe and I sample probe
with collision protection, liquid level detection
.Reagent probe
with reagent preheating
.Power
AC 110V/220V, 50-6011 Hz
.Water consumption
6Uhour
.Dimension LxW二H (mm)
820x680x550
.Weight
100Kg
.8 clotting detection channels
660nm
.5 transmission detection channels
(for both Chromogenic assays
standard wavelengths
405nm, 575nm, 660nm, 800nm

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.