Automated blood coagulation analyzer RAC-1800 for sale
MODEL / RAC-1800Automated blood coagulation analyzer RAC-1800 for sale. Clotting Method: PT, APTT, TT, FIB, etc.
- 一Automatic, Random Access
- 一Clotting, Chromogenic, Immunologic measuring methods
- 一188 tests/hour for PT
- 一86 tests/hour for D-Dimer
Product Details
Quick Details
一Automatic, Random Access
一Clotting, Chromogenic, Immunologic measuring methods
一188 tests/hour for PT
一86 tests/hour for D-Dimer
Specifications
Automated coagulation analyzer RAC-1800
Automated coagulation analyzer RAC-1800 Features
一Automatic, Random Access
一Clotting, Chromogenic, Immunologic measuring methods
一188 tests/hour for PT
一86 tests/hour for D-Dimer
一Autoloader for cuvettes
一User-friendly operation software
一Bi-directional LIS system
一 STAT sample priority
一Reagent open system, close system on request
一Barcode-reading for sample and reagent (Optional)

Automated coagulation analyzer RAC-1800 Technical Specifications
System Function
.Throughput: 188 tests/hour for PT
86 tests/hour for D-Dimer
.Measuring methods and parameters:
Clotting Method: PT, APTT, TT, FIB, etc.
Chromogenic Method: AT-iii, PLG, a2-AP, PC,
Heparin, etc.
Immunologic Method: D-Dimer, FDP, etc.
Sample Tray
.Sample tray: 55 positions
user一efined STAT
Reagent Tray
.Reagent tray: 24 positions with cooling怕nction
5 positions without cooling function
.Reagent cooling: <16℃
Reaction Tray
.Cuvettes on board:300
.Min reaction volume: 150u1
.Incubators positions: 18
.Reaction temperature: 3710.50C
Automated coagulation analyzer RAC-1800 Probe
.1 reagent probe and I sample probe:
with collision protection, liquid level detection
and inventory checking function.
.Reagent probe: with reagent preheating,
and overheating protection function.
Print out
.External PC controlled printer
Others
.Power: AC 110V/220V, 50-6011 Hz
.Water consumption: 6Uhour
.Dimension LxW二H (mm):820x680x550
.Weight: 100Kg
Automated coagulation analyzer RAC-1800 Optical System
.LED light
.8 clotting detection channels,
660nm
.5 transmission detection channels,
(for both Chromogenic assays
and Immunologic assays),
4 standard wavelengths:
405nm, 575nm, 660nm, 800nm,
2 more optional
(from 400nm-900nm)
Technical Specifications
Technical parameters from the currently available product information.
- .Throughput
- 188 tests/hour for PT
- Chromogenic Method
- AT-iii, PLG, a2-AP, PC
- .Sample tray
- 55 positions
- .Reagent tray
- 24 positions with cooling怕nction
- .Reagent cooling
- <16℃
- .Cuvettes on board
- 300
- .Min reaction volume
- 150u1
- .Incubators positions
- 18
- .Reaction temperature
- 3710.50C
- .1 reagent probe and I sample probe
- with collision protection, liquid level detection
- .Reagent probe
- with reagent preheating
- .Power
- AC 110V/220V, 50-6011 Hz
- .Water consumption
- 6Uhour
- .Dimension LxW二H (mm)
- 820x680x550
- .Weight
- 100Kg
- .8 clotting detection channels
- 660nm
- .5 transmission detection channels
- (for both Chromogenic assays
- standard wavelengths
- 405nm, 575nm, 660nm, 800nm
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.