Best Professional Auto-Chemistry Analyzer CS-T240 from Medsinglong
MODEL / CS-T240Best Professional Auto-Chemistry Analyzer CS-T240 from Medsinglong. Discrete, colorimetry speed 240T/H(single/double reagent).
- Discrete, colorimetry speed 240T/H(single/double reagent).
- Rear spectrophotometry of holographic concave flat field grating, cluster-optical path, enables micro volume detection of reaction solution
- 60nm polished probe, liquid level detection and collision protection
- Automatic digital liquid level detection, ensures stable performance, and reduces contamination carried by probe surface.
Product Details
Quick Details
Overall performance Equipment type: Fully automatic, discrete, STAT priority Analysis rate: colorimetry speed 240T/H(single/double reagent) Test principle: Colorimetry, turbidimetry Analysis method: End-point, kinetics, fixed-time, etc. support single/double wavelength and 1-2 multiple reagent item, liner and non-liner calibration
Specifications
Features of Auto-Chemistry Analyzer CS-T240:
1.Auto-Chemistry Analyzer CS-T240 2.Discrete, colorimetry speed 240T/H(single/double reagent). 3.Rear spectrophotometry of holographic concave flat field grating, cluster-optical path, enables micro volume detection of reaction solution 4.60nm polished probe, liquid level detection and collision protection 5.Automatic digital liquid level detection, ensures stable performance, and reduces contamination carried by probe surface. 6.Multiple function sample reagent disk, sample position and reagent position, users defined proportion according to the requirement, supporting various tubes and standard sample cuvettes. 7.LIS/HIS interface, also supports remote maintenance. 8.User-defined combined batch input of patient information, applicable to all customers' laboratories


Specification of Auto-Chemistry Analyzer CS-T240:
1.Overall performance Equipment type: Fully automatic, discrete, STAT priority Analysis rate: colorimetry speed 240T/H(single/double reagent) Test principle: Colorimetry, turbidimetry Analysis method: End-point, kinetics, fixed-time, etc. support single/double wavelength and 1-2 multiple reagent item, liner and non-liner calibration
2.Sample reagent unit Sample reagent position: the reagent and sample share one disk, totally 67 positions. Continuously cooling at all positions to keep 5-15℃within 24h Sample cuvettes specification Standard cup, original blood tube, multi-specification tube available (Φ12~16)mm×(25~100)mm Sample volume: 3μl-35μl,0.1 stepping Reagent volume R1:10μl-350μl,R2:10μl-200μl,1μlstepping Sample reagent probe Liquid level detection and collision detection

3.Reaction unit Reaction cuvette 120 positions optical plastic cup Total volume of reaction liquid 150μl~550μl Reaction temperature 37℃ Reaction disk constant temperature: circulating water Mixer Mix immediately after adding reagent Wastewater treatment With the function of concentrated waste liquid level alarming
4.Optical system Light source 20W/12V halogen lamps. Monochromator Grating photometry Photoelectron road After spectrophotometry Wavelengths 340nm~800nm Detector Photodiode LED array
5.Calibration and QC Calibration method 1 point linear method, 2 point linear method, multiple point linear method, non-linear method Calibration tracking: Automatic description calibration K-value trends QC method Real-time QC, daily QC and monthly QC Out of control processing: Alarming for out of control sample, record lost control reason

6.Operating system PC operating system Windows XP Analysis control software Graphical operating software English version Report printing Report formats support the user-defined mode, QC and state information etc. System connection TCP/IP network connection, standard RS-232C
7.Others Volume 998mm×752mm×517mm Weight 120kg Power supply Voltage AC 220V-22V, 50/60Hz, power 600VA

Technical Specifications
Technical parameters from the currently available product information.
- Equipment type
- Fully automatic, discrete, STAT priority
- Analysis rate
- colorimetry speed 240T/H(single/double reagent)
- Analysis method
- End-point, kinetics, fixed-time, etc. support single/double wavelength and 1-2 multiple reagent item, liner and non-liner calibration
- Discrete, colorimetry speed
- 240T/H(single/double reagent).
- Sample reagent position
- the reagent and sample share one disk, totally 67 positions. Continuously cooling at all positions to keep 5-15℃within 24h
- Sample volume
- 3μl-35μl,0.1 stepping
- Reagent volume R1
- 10μl-350μl,R2:10μl-200μl,1μlstepping
- Reaction disk constant temperature
- circulating water
- Calibration tracking
- Automatic description calibration K-value trends
- Out of control processing
- Alarming for out of control sample, record lost control reason
- Power supply Voltage AC
- 220V-22V, 50/60Hz, power 600VA
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team