Bubble CPAP versus Ventilator CPAP in Preterm Neonates with Early Onset Respiratory Distress EKONVM25
MODEL / EKONVM25This CPAP system could provides continuous positive airway pressure based on Non-invasive ventilation , and used for treating infant slightly respiratory failure. But the infant should have spontaneous breath. This unit could apply in Pediatrics and Neonatology.
- Equipped with built-in oxygen/air blender, ensuring O2 concentration adjustment to be stable
- High quality oxygen sensor can monitor real-time O2 concentration , alarm over limitation, ensure safety of breathing O2
- Reliable CPAP control valve and advanced pressure monitoring system improve CPAP adjustment precision.
- Made by Aluminum Alloy, very stable and durable.
Product Details
Quick Details
Basic Function
- Basing on NCPAP ventilation mode
- Offer properly adjusted O2 concentration
- mechanically ventilated
Specifications
Intended Usage:
This CPAP system could provides continuous positive airway pressure based on Non-invasive ventilation, and used for treating infant slightly respiratory failure. But the infant should have spontaneous breath. This unit could apply in Pediatrics and Neonatology.
Basic Function
Basing on NCPAP ventilation mode Offer properly adjusted O2 concentration mechanically ventilated

Performance and features
Working condition Air source O2、AIR Air source pressure 280 kPa ~ 600 kPa Power supply ~220 V±22 V, 50 HZ with air compressor 100-240V,50/60HZ(without air compressor) Input power 900VA(with air compressor) 250VA (without air compressor)
Ventilation Mode CPAP
Main technical parameters Adjusting Parameter Inhaled oxygen concentration 21 %~100 % CPAP 0cmH2O~15 cmH2O Continuous flow 2L/min~20L/min
Monitoring Parameter Inhaled oxygen concentration 15 % ~ 100 % CPAP 0 cmH2O ~ 60 cmH2O Continuous flow 2 L/min ~ 20 L/min

Alarm and protection The AC power cut-off alarm Low air (oxygen) input pressure alarm Air / oxygen input unbalanced pressure alarm High oxygen concentration alarm low oxygen concentration alarm Pressure limit
The main structure-EKONVM26 Main Unit(gas parameter adjustment, display, security and alarm systems, oxygen and air mixing device, the oxygen concentration meter, the patient connector), medical air compressor (optional), gas supply,tubing rack.
Accessories
Optional parts: humidifier with heating device, which could avoid dry gas harm for respiratory tract.
Air compressor: Optional air compressor Input power: 900VA
Hanging bracket: Made by Aluminum Alloy, very stable and durable.
Recycling Breathing Circuit: Made of Silica Gel, could be recycled use
High-pressure pipe: Very strong and durable
Nasal Cannula
EKONVM25 Detail Configuration
18 Infant breathing Tube 1000mm 2 PCS 600mm 2 PCS 300mm 1 PCS Water collector φ10 Children 2 PCS connector 8.653.033 2 PCS BN11/Babi-Plus Neonatal Breathing circuit 1 Set Luer Taper 3/32(2.4 Inside Thread PC) 4 PCS
Technical Specifications
Technical parameters from the currently available product information.
- Air source pressure 280 kPa ~
- 600 kPa
- Power supply ~220 V±22 V
- 50 HZ with air compressor
- Continuous flow 2 L/min ~
- 20 L/min
- Input power
- 900VA
- High pressure O2 hose
- 4.472.004 1 PCS
- Hose for airway pressure
- 4.472.006 1 PCS
- Power line
- 0.6M 1 PCS
- Power line(006)
- 4M 1 PCS
- Oxygen Sensor OOM202-1
- 1 PCS
- Infant breathing Tube
- 1000mm 2 PCS
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.