Buy Portable Postpartum Rehabilitation Instrument EKONPR05
MODEL / EKONPR05Buy Portable Postpartum Rehabilitation Instrument EKONPR05. Treat time:15-65 minutes,error is 1 minute.
- It can bear the influence from open circuit and short circuit, the function is no weaken.
Product Details
Quick Details
Output pulse width:0.4ms±10% Single pulse electricity:>7μc Single pulse power: ≤300mJ Open-way output peak value:≤500Vp-p Max output range value:≤40V Output range adjustment: power output range is 0~260, increase or dis crease progressively in proper sequence, it is steady consecutively, Min output is 2%. Treat time:15-65 minutes,error is 1 minute. It can bear the influence from open circuit and short circuit, the function is no weaken. When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output Working mode: continuously Input:≤100VA
Specifications
Specification of Portable Postpartum Rehabilitation Instrument EKONPR05:
Three-channel output, Basic Pulse wave is rectangle wave, Basic pulse frequency:800Hz±8%. Adjusting wave and frequency:trapezoid wave 0.5-10Hz,triangle wave 1-20Hz,bell wave 0.5-10Hz (no adjusting wave below 40) Output pulse width:0.4ms±10% Single pulse electricity:>7μc Single pulse power: ≤300mJ Open-way output peak value:≤500Vp-p Max output range value:≤40V Output range adjustment: power output range is 0~260, increase or dis crease progressively in proper sequence, it is steady consecutively, Min output is 2%. Treat time:15-65 minutes,error is 1 minute. It can bear the influence from open circuit and short circuit, the function is no weaken. When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output Working mode: continuously Input:≤100VA


Application of Portable Postpartum Rehabilitation Instrument EKONPR05:
Lactation lack at Post partum Dredge breast Mammitis The recovery of the uterus Diastasis recti abdominis Chronic pelvic inflammation and vaginal relaxation Retention of urine Postoperative analgesia Pelvic floor muscle repair Body recovery



Technical Specifications
Technical parameters from the currently available product information.
- Output pulse width
- 0.4ms±10%
- Single pulse electricity
- >7μc
- Single pulse power
- ≤300mJ
- Open-way output peak value
- ≤500Vp-p
- Max output range value
- ≤40V
- Output range adjustment
- power output range is 0~260, increase or dis crease progressively in proper sequence, it is steady consecutively, Min output is 2%.
- Treat time
- 15-65 minutes,error is 1 minute.
- When output range is exceed
- 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output
- Working mode
- continuously
- Input
- ≤100VA
- Adjusting wave and frequency
- trapezoid wave 0.5-10Hz,triangle wave 1-20Hz,bell wave 0.5-10Hz (no adjusting wave below 40)
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.