Other

Buy Portable Postpartum Rehabilitation Instrument EKONPR05

MODEL / EKONPR05

Buy Portable Postpartum Rehabilitation Instrument EKONPR05. Treat time:15-65 minutes,error is 1 minute.

  • It can bear the influence from open circuit and short circuit, the function is no weaken.
PRODUCT OVERVIEW

Product Details

Quick Details

Output pulse width:0.4ms±10% Single pulse electricity:>7μc Single pulse power: ≤300mJ Open-way output peak value:≤500Vp-p Max output range value:≤40V Output range adjustment: power output range is 0~260, increase or dis crease progressively in proper sequence, it is steady consecutively, Min output is 2%. Treat time:15-65 minutes,error is 1 minute. It can bear the influence from open circuit and short circuit, the function is no weaken. When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output Working mode: continuously Input:≤100VA

Specifications

Specification of Portable Postpartum Rehabilitation Instrument EKONPR05:

Three-channel output, Basic Pulse wave is rectangle wave, Basic pulse frequency:800Hz±8%. Adjusting wave and frequency:trapezoid wave 0.5-10Hz,triangle wave 1-20Hz,bell wave 0.5-10Hz (no adjusting wave below 40) Output pulse width:0.4ms±10% Single pulse electricity:>7μc Single pulse power: ≤300mJ Open-way output peak value:≤500Vp-p Max output range value:≤40V Output range adjustment: power output range is 0~260, increase or dis crease progressively in proper sequence, it is steady consecutively, Min output is 2%. Treat time:15-65 minutes,error is 1 minute. It can bear the influence from open circuit and short circuit, the function is no weaken. When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output Working mode: continuously Input:≤100VA

Buy Portable Postpartum Rehabilitation Instrument EKONPR05
Buy Portable Postpartum Rehabilitation Instrument EKONPR05

Application of Portable Postpartum Rehabilitation Instrument EKONPR05:

Lactation lack at Post partum Dredge breast Mammitis The recovery of the uterus Diastasis recti abdominis Chronic pelvic inflammation and vaginal relaxation Retention of urine Postoperative analgesia Pelvic floor muscle repair Body recovery

Buy Portable Postpartum Rehabilitation Instrument EKONPR05
Buy Portable Postpartum Rehabilitation Instrument EKONPR05
Buy Portable Postpartum Rehabilitation Instrument EKONPR05
TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Output pulse width
0.4ms±10%
Single pulse electricity
>7μc
Single pulse power
≤300mJ
Open-way output peak value
≤500Vp-p
Max output range value
≤40V
Output range adjustment
power output range is 0~260, increase or dis crease progressively in proper sequence, it is steady consecutively, Min output is 2%.
Treat time
15-65 minutes,error is 1 minute.
When output range is exceed
10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output
Working mode
continuously
Input
≤100VA
Adjusting wave and frequency
trapezoid wave 0.5-10Hz,triangle wave 1-20Hz,bell wave 0.5-10Hz (no adjusting wave below 40)

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us