Buy Real-Time pcr thermal cycler detection system EKONPCR06 from Medsinglong

MODEL / EKONPCR06

Please note: Power supply is defaulted as standard configuration.Please remark on special request.Shipment date for special request might be later than standard configuration, please contact our salesperson to confirm.

  • Multiple control:support
  • Standard configuration 220V/50HZ
  • Available upon special request 220V/60HZ,110V/60HZ
  • Please note: Power supply is defaulted as standard configuration.Please remark on special request.Shipment date for special request might be later than standard configuration, please contact our salesperson to confirm.
PRODUCT OVERVIEW

Product Details

Quick Details

Model:EKONPCR06A Channel:2 Reaction per run:96 Block Format:96-well 0.2 ml Color combinations:Up to 2 Light Source:High brightness monochrome LED Detector:High sensitive cold light CCD Detection dynamic range:10^2~10^10 Sensitivity:Down to 1 copy Reaction volume:15ul -100ul

Specifications

Order No.:EKONPCR06B

Buy Real-Time pcr thermal cycler detection system EKONPCR06 from Medsinglong
Buy Real-Time pcr thermal cycler detection system EKONPCR06 from Medsinglong

Which real-time or digital PCR system is right for you?

To understand why traditional PCR is limited, it is important to understand what happens during the PCR reaction. A basic PCR run can be divided into three phases:

Index period

Accumulated product exactly doubles with each cycle (assuming 100% reaction efficiency). The reaction is highly specific and precise. Exponential amplification occurs because all reagents are freshly available and the kinetics of the reaction drive the reaction in favor of amplicon doubling.

Linear phase (high variability) As the reaction continues, some reagents are consumed by amplification. The reaction starts to slow down, and the PCR product no longer doubles with each cycle.

Plateau (endpoint: gel detection using conventional methods) The reaction stops, no more product is produced, and if left long enough, the PCR product will start to degrade. Because each sample has different reaction kinetics, each tube or reaction will plateau at a different time point. These differences can be seen during the plateau. During the plateau period, conventional PCR performs the measurement, also known as endpoint detection.

Variation in plateau measurements with conventional PCR Three replicate samples had the same amount of DNA at the start of the reaction and different amounts of PCR product during the plateau phase of the reaction (due to changes in reaction kinetics). Therefore, it will be more accurate to make measurements during the exponential period, where replicate samples expand exponentially.

Real-time PCR measures during exponential phase for more accurate quantitation Real-time PCR focuses on the exponential phase because it provides more precise data for quantification. During the exponential period, the real-time PCR instrument calculates two values. The threshold line is the level of detection at which the fluorescence intensity of the reaction exceeds background. The PCR cycle at which the sample reaches this level is called the cycle threshold (Ct). Ct values are used for downstream quantification or presence/absence detection. By comparing the Ct values of a sample of unknown concentration with a series of standards, the amount of template DNA in an unknown reaction can be accurately determined.

Digital PCR counts individual molecules for absolute quantification Digital PCR works by splitting the sample into many individual real-time PCR reactions; some of these reactions contain the molecule of interest (positive) and others do not (negative). After PCR analysis, a fraction of the negative results are used to generate absolute results for the exact amount of target molecule in the sample without the need for reference standards or endogenous controls.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Channel
2
Reaction per run
96
Block Format
96-well 0.2 ml
Color combinations
Up to 2
Detector
High sensitive cold light CCD
Detection dynamic range
10^2~10^10
Sensitivity
Down to 1 copy
Reaction volume
15ul -100ul
Order No.
EKONPCR06A
Chemistry
all real-time PCR-based chmistries.Flexibility for chemistries with or without passive reference dye
Excitation filters/colors
Channel 1- 470nm; Channel 2- 525nm
Detection filters/colors
Channel 1- 525nm; Channel 2- 570nm
Kits & Reagent
Channel 1- FAM/SYBR; Channel 2- VIC/HEX/JOE/TET/TAMRA
Block Material
Peltier
Accuracy
≤±0.1℃
Uniformity
±0.4℃ (10 sec after reaching 95℃); ±0.2℃ (10 sec after reaching 55℃)
Temperature range
0-100℃
Max ramp rate
6℃

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.