Cost effective Pediatric ventilator ICU ventilaor machine EKONVM34
MODEL / EKONVM34dysfunction, intra-operation and post-operating respiratory support, and other respiratory treatments.
- respiratory support, acute respiratory failure caused by various reasons or incomplete oxygenation
- dysfunction, intra-operation and post-operating respiratory support, and other respiratory treatments.
- Prossure support (PS) 0 cmH2O ~ 80 cmH2O
- ■Air compressor runs stably with low noise, creates quiet environment for doctors and patients.
Product Details
Quick Details
- The ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation
- respiratory support, acute respiratory failure caused by various reasons or incomplete oxygenation
- dysfunction, intra-operation and post-operating respiratory support, and other respiratory treatments.
Specifications
Technical Specifications
Ventilation modes IPPV, AC, PCV, SIMV, SPONT/CPAP, PSV
Ventilator parameter ranges Tidal volume (V4) 0一2000ml Frequency (Freq) 1bpm~100bpm Oxygen concentration 21%一100% I/E 4:1~1:8 PEEP 0cmH2O ~ 40 cmH2O Pressure tigging sensitvity (PTr) -20 cmH2O ~ 20 cmH,O (Based onPEEP) Flow trgger sensitivity (FTr) 0.5 L/min - 30 Lmin Pressure control (PC) 5 cmH2O ~ 80 cmH2O Prossure support (PS) 0 cmH2O ~ 80 cmH2O SIGH 0 (f) 1/100 ~ 5/100 Apnea ventilation OFF, 5s-60s Pressure limit 20 cmH2O ~ 100 cmH2O

Monitored parameters Frequency (Freq) 0/min ~ 100/ min Tidal volume(V1) 0ml-2500ml MV 0 U/min ~ 99 L/min Airway pressure 0 cmH2O ~ 100 cmH2O Dynarmic lung complance testing 1 ml /cmH2O - 1000 ml /cmH2O ETCO: concentration 0mmHg-152mmHg(0%~20%) Oxygen concentration 15%一100%
Wooden case packing size Main components: L 560 * W 560 " H 605 mm G.W.:35 KG, N.W.: 17 KG Air compressor; L 670* W 700* H 1160 mm G.W.: 79 KG, N.W.:46.2 KG
Alarm and protection AC power failure alarm Power failure or no connection Intemal backup battery low voltage alams ≤11.3+0.3V No tidal volume No tidal volume within 6s High minute volume alarm 5 L/min ~ 99 Lmin Low minute volume alarm 1 L/min ~ 30 Umin High airway pressure alarm 20 cmH2O ~ 100 cmH2O Low airway pressure alarm 0 cmH2O ~ 20 cmH2O High oxygen concentration alarm 19%一100% Low oxygen concentration alarm 18 %~99 % Continuous pressure alarm (PEEP+ 1.5 cmH,O) over 16s Sullocation warning 5~60s Fan error Show on screen Oxygen deficit Show on screen The maximum limited pressure <12.5 kPa
Working conditions Gas source O2 AIR Pressure 280 kPa- 600 kPa Voltage 220V±22V Power frequency 50Hz±1 Hz Input power 900 VA (With air compressor) 250 VA (Without air compressor)
oscillographs display P.T (Pressure. time) F.T (Flow. time) P.V loop (Pressure - volume loop) V.T (Volume - time ) ETCO,- T (End-tidal CO2 - time)

Application
The ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation respiratory support, acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction, intra-operation and post-operating respiratory support, and other respiratory treatments.
Features
■15" TFT LCD touch screen displays the ventilation parameters, alarm information and oscillographs. Touch screen makes the operation more simple. ■Air compressor runs stably with low noise, creates quiet environment for doctors and patients. ' Recyclable silicon breathing circuit, ensure easy operation and keep tidy ■Multiple working modes such as volume control and pressure limit, adapt to wide ranges of patients. ”Multiple parameters monitoring interface, make every parameter clear, let users know the patient condtions in all aspects. ' Real time pressure-tme, flow time, volume time, ETCO2 (End-tidal CO2 - time), pressure volume loop osillographs, and high precision oxygen concentration detection function included. ■Electronic PEEP control.
Breathing valve can be disassembled and disinfect.

Safety
■Three levels alarm system, come with visual and audible alarm information. ■With lots of alarm, reminder and protection functions. ' Advanced power management control technology. ■Billt-in backup battery provides the emergency power supply to the unit. ■Sellf-check before running, eliminate system mistake. Separate design of electric circuit and gas flow route, keep safe running of ventilator.
14 types of alarm and protection function, 15" TFT LCD screen display screen saver mode 3 of 5 oscillographs can be displayed on the screen at the same time 2 minutes fast oxygen supply Parameters setting Parameters monitoring Nebulization function Oxygen concentration sensor Humidifier Heating and wetting, real-time temperature display Display continuous working hours for the air compressor
Technical Specifications
Technical parameters from the currently available product information.
- I/E 4
- 1~1:8
- Pressure tigging sensitvity (PTr) -20 cmH2O ~
- 20 cmH,O (Based onPEEP)
- Flow trgger sensitivity (FTr)
- 0.5 L/min - 30 Lmin
- Pressure control (PC) 5 cmH2O ~
- 80 cmH2O
- Pressure limit 20 cmH2O ~
- 100 cmH2O
- Frequency (Freq) 0/min ~
- 100/ min
- Airway pressure 0 cmH2O ~
- 100 cmH2O
- ETCO
- concentration 0mmHg-152mmHg(0%~20%)
- Main components
- L 560 * W 560 " H 605 mm
- G.W.
- 35 KG, N.W.: 17 KG
- Intemal backup battery low voltage alams
- ≤11.3+0.3V
- High airway pressure alarm 20 cmH2O ~
- 100 cmH2O
- Low airway pressure alarm 0 cmH2O ~
- 20 cmH2O
- Continuous pressure alarm (PEEP+
- 1.5 cmH,O) over 16s
- Pressure
- 280 kPa- 600 kPa
- Input power
- 900 VA (With air compressor)
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.