Other

Cost effective Portable Postpartum Rehabilitation Instrument EKONPR02 for sale

MODEL / EKONPR02

It can bear the influence from open circuit and short circuit, the function is no weaken.

  • It can bear the influence from open circuit and short circuit, the function is no weaken.
PRODUCT OVERVIEW

Product Details

Quick Details

Output pulse width:0.4ms±10% Single pulse electricity:>7μc Single pulse power: ≤300mJ Open-way output peak value:≤500Vp-p Max output range value:≤40V Output range adjustment: power output range is 0~260, increase or dis crease progressively in proper sequence, it is steady consecutively, Min output is 2%. Treat time:15-65 minutes,error is 1 minute, It can bear the influence from open circuit and short circuit, the function is no weaken. When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output Working mode: continuously Input:≤100VA Working mode: Continuous progress

Specifications

Specification of Portable Postpartum Rehabilitation Instrument EKONPR02:

Four-channel output, Basic Pulse wave is rectangle wave, Basic pulse frequency:800Hz±5%. Adjusting wave and frequency:trapezoid wave 0.5-10Hz,triangle wave 1-20Hz,bell wave 0.5-10Hz (no adjusting wave below 40) Output pulse width:0.4ms±10% Single pulse electricity:>7μc Single pulse power: ≤300mJ Open-way output peak value:≤500Vp-p Max output range value:≤40V Output range adjustment: power output range is 0~260, increase or dis crease progressively in proper sequence, it is steady consecutively, Min output is 2%. Treat time:15-65 minutes,error is 1 minute, It can bear the influence from open circuit and short circuit, the function is no weaken. When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output Working mode: continuously Input:≤100VA Working mode: Continuous progress

Cost effective Portable Postpartum Rehabilitation Instrument EKONPR02 for sale
Cost effective Portable Postpartum Rehabilitation Instrument EKONPR02 for sale

Application of Portable Postpartum Rehabilitation Instrument EKONPR02:

Lactation lack at Post partum Dredge breast Mammitis The recovery of the uterus Diastasis recti abdominis Chronic pelvic inflammation and vaginal relaxation Retention of urine Postoperative analgesia Pelvic floor muscle repair Body recovery

Cost effective Portable Postpartum Rehabilitation Instrument EKONPR02 for sale
Cost effective Portable Postpartum Rehabilitation Instrument EKONPR02 for sale
TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Output pulse width
0.4ms±10%
Single pulse electricity
>7μc
Single pulse power
≤300mJ
Open-way output peak value
≤500Vp-p
Max output range value
≤40V
Output range adjustment
power output range is 0~260, increase or dis crease progressively in proper sequence, it is steady consecutively, Min output is 2%.
Treat time
15-65 minutes,error is 1 minute
When output range is exceed
10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output
Working mode
continuously
Input
≤100VA
Adjusting wave and frequency
trapezoid wave 0.5-10Hz,triangle wave 1-20Hz,bell wave 0.5-10Hz (no adjusting wave below 40)

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us