Ultrasound > Chison ultrasound

Doppler vascular Chison ECO6 price

MODEL / Chison ECO6

8 TGC Slides for Easy Adjustment; High resolution color LED; System status (real-time or frozen).

  • 8 TGC Slides for Easy Adjustment
  • High resolution color LED
  • System status (real-time or frozen)
  • High resolution 12 Inch LED display
PRODUCT OVERVIEW

Product Details

Quick Details

Image Modes

B Mode

B/M Mode

M Mode

2B Mode

4B Mode

B steer

CFM Mode

CPA Mode

DPD Mode

D(PW) Mode

B/BC Mode

Triplex Mode

CW Mode (option)

TDI (option)

Trapezoidal Mode

Specifications

Doppler vascular Chison ECO6 price

Doppler vascular Chison ECO6 Dimensions and Weight

Dimensions of main unit (approx.):

335 mm (Length) * 155 mm (Width) * 350 mm (Height)

Net weight of main unit (approx): 6.5 kg (no probe included)

Electrical Power

Adapter Power supply voltage: AC100-240V 50/60Hz

Main system power input: 19V 3.15A

Battery type:BT-2500 Li-ion 14.4V 4400mAh

General

Information

Chison ECO6

Doppler vascular Chison ECO6 Operation Keyboard

Fold-up Control Panel and Alphanumeric Keyboard

Back-lit Keyboard for Good Visibility in Dark Room

Interactive Back-Lighting

Indicator Lights Identify Activated Keys

8 TGC Slides for Easy Adjustment

Short Cut knob for Quick Adjustment

Neat & Clear Keyboard Layout, Doctor Can Remember Easily

Print Directly from the Keyboard

Display Screen

High resolution color LED

- Diagonal dimension: 12 inch

- Resolution: 1024 x 768

- Angle adjustable: 0-30 o

User

Interface

Chison ultrasound Chison ECO6

Doppler vascular Chison ECO6 Applications

Abdomen

Cardiology

Obstetrics

Gynecology

Urology

Vascular

Small Parts

Pediatrics

MSK

Nerve

Scanning Method

Electronic convex

Electronic linear

Electronic micro- convex

Electronic phased array

Transducer Types

C3-A convex probe, center frequency 3.5MHz

V6 -A micro-convex probe, center frequency 6.0MHz

L7M -A linear probe, center frequency 7.5MHz

MC3-A micro-convex probe, center frequency 3.0MHz

L7S-A linear probe, center frequency 7.5MHz

R7-A rectal probe, center frequency 7.5MHz

MC6-A micro-convex probe, center frequency 6.0MHz

P3-A Phased array transducer 3.0MHz

System

Overview

Doppler vascular Chison ECO6 Image Modes

B Mode

B/M Mode

M Mode

2B Mode

4B Mode

B steer

CFM Mode

CPA Mode

DPD Mode

D(PW) Mode

B/BC Mode

Triplex Mode

CW Mode (option)

TDI (option)

Trapezoidal Mode

Super Needle (option)

Display Mode

Quad/dual display (Only for B)

Duplex mode: B+CFM, B+CPA, B+DPD, B/M

Triplex mode: B+CFM+PW, B+CPA+PW, B+DPD+PW,

Display Annotation

Institution/Hospital name

Date/Time

Patient Name and Patient ID

System status (real-time or frozen)

Gray bar

Cine guide

Scanning direction

Measurement summary window

Measurement results window

Probe type

Application name

Eco doppler carotidian Chison ECO6

Doppler vascular Chison ECO6 Menu indication

Imaging parameters displayed on the screen

Standard Configuration

High resolution 12 Inch LED display

2 active probe ports

16G high speed memory (500G hard disk optional)

USB ports: left side 2, back 1

Ethernet port

video out port

remote port

VGA port

Foot switch port

Multi-language screen display

EASYVIEW TM: image archive system

Patient information management system

Built-in reporting system

Intelligent Zoom

Multiple Compound Imaging (MCI)

Speckle Reduction Imaging(SRA)

i-Image

Full screen show

BT-2500 li-ion battery

Software Options

DICOM 3.0

Hardware Options

C3-A convex probe, center frequency 3.5MHz

V6 -A micro-convex probe, center frequency 6.0MHz

L7M -A linear probe, center frequency 7.5MHz

MC3-A micro-convex probe, center frequency 3.0MHz

L7S-A linear probe, center frequency 7.5MHz

R7-A rectal probe, center frequency 7.5MHz

MC6-A micro-convex probe, center frequency 6.0MHz

P3-A Phased array transducer 3.0MHz

Biopsy guide for C3-A, L7M-A, V6-A

Carry bag BG-100

Trolley TR-9000

Peripherals

Video printer:

Mitsubishi P93W

Sony UP-897MD

Sony UP-D711MD

Sony UP-X898MD

PC printer:

HP LaserJet P2055

HP LaserJet Pro 200 Color M251n

HP LaserJet Pro P1102

HP LaserJet 1020

HP LaserJet Pro P1102w

HP Deskjet 1010 series

HP Color LaserJet Pro M252dw

HP Color LaserJet Pro M252n

HP Officejet Pro 6230

OKI C331

OKI C711

EPSON L130

B Mode

Scan width(14%~100%))

Focus number (1~4, depend on the probe types)

Persistence(0~7)

Dynamic (30~90)

Imaging

Processing and

Presentation

Density (Low,High)

Smooth (0~7)

Edge enhancement (0~6)

A power (0-100%)

4B

Frequency(depend on the probe types)

i-Image(0~3)

Compound (On, Off)

SRA (On, Off)

2B

CPA

CW(Only for Phased array transducer) (Option)

TDI(Only for Phased array transducer) (Option)

GAIN (0~255)

STC (8 segments)

Depth(2.5~24.6cm, depend on the probe types)

Focus position (depend on the probe types)

Invert (left/right, up/down)

Zoom(Max16 steps, depend on the probe types and Depth)

Zoom coef(60%~100%)

Trapezoidal Mode(On,Off, only for linear transducer)

B steer(-20°~+20°, only for linear transducer)

Biopsy(On,Off)

Super Needle(On,Off, only for L7M-A and L7S-A transducer)(Option)

Needle Angle(-30°~+30°, only for L7M-A and L7S-A transducer) (Option)

Center Line(On,Off)

FPS(Frame Rate)

Utility Menu

Chroma(0~28)

2D Map(Default,1~20)

Gamma(0~8)

B rejection(0-256)

Slide Show

M Mode

ecografie transfontanelara Chison ECO6

Speed (1~4)

M Chroma(0~8)

M 2D Map(Default,1~20)

M Gamma(0~8)

Layout(LR,UD)

C Mode

CPA

CF Mode(Velocity,Variance)

Color Invert(On,Off)

Steering Angle(-20°~+20°,only for linear transducer)

Color Map(0~8)

Wall Filter(0~3)

Wall Thre.(0~14)

Blood Effection(Smooth,Resolution,Resolution2,Resolution3)

Density(Low,High)

B/BC(On,Off)

Freq(depend on the probe types)

Base Line(-3~3)

PRF(depend on the probe types and ROI position)

Persistence(0~7)

CW(Only for Phased array transducer) (Option)

TDI(Only for Phased array transducer) (Option)

CF GAIN(0~255)

ROI Size

FPS(Frame Rate)

CPA Mode

DPD

Steering Angle(-20°~+20°,only for linear transducer)

Wall Filter(0~3)

Wall Thre.(0~14)

Blood Effection(Smooth,Resolution,Resolution2,Resolution3)

Density(Low,High)

Freq(depend on the probe types)

PRF(depend on the probe types and ROI position)

Persistence(0~7)

TDI(Only for Phased array transducer) (Option)

CPA GAIN(0~255)

ROI Size

DPD Mode

CPA

Steering Angle(-20°~+20°,only for linear transducer)

Wall Filter(0~3)

Color Invert(On,Off)

Wall Thre.(0~14)

Blood Effection(Smooth,Resolution,Resolution2,Resolution3)

Density(Low,High)

Freq(depend on the probe types)

Base Line(-3~3)

PRF(depend on the probe types and ROI position)

Persistence(0~7)

CW(Only for Phased array transducer) (Option)

TDI(Only for Phased array transducer) (Option)

CPA GAIN(0~255)

ROI Size

D(PW) Mode

D 2D Map(Default,1~20)

Spectrum Enhance(0~3)

Dynamic Range(46~67)

Chroma(0~28)

Wall Filter(0~3)

Audio(0~100%)

Steering Angle(-20°~+20°,only for linear transducer)

Angle(0°~70°)

Invert(On,Off)

Freq(depend on the probe types)

Base Line(-3~3)

PRF(depend on the probe types and Gate position)

Triplex Mode(Off,On)

Speed(0~2)

CW(Only for Phased array transducer) (Option)

TDI(Only for Phased array transducer) (Option)

D GAIN(0~255)

SV(0.5-20mm)

TDI mode(Option)

Wall Thre.(0~14)

Blood Effection(Smooth,Resolution,Resolution2,Resolution3)

Wall Filter(0~3)

Color Map(0~10)

Color Invert(On,Off)

Density(Low,High)

Freq(depend on the probe types)

Base Line(-3~3)

PRF(depend on the probe types and ROI position)

Persistence(0~7)

CW(Only for Phased array transducer) (Option)

TDI(Only for Phased array transducer) (Option)

TDI Gain

ROI Size

CW mode(Option)

CW 2D Map(Default,1~20)

Spectrum Enhance(0~3)

Dynamic Range(46~67)

CWD Chroma(0~8)

Wall Filter(0~3)

Audio(0~100%)

Invert(On,Off)

Freq(depend on the probe types)

Base Line(-3~3)

PRF(depend on the probe types )

Speed(0~2)

CW(Only for Phased array transducer) (Option)

TDI(Only for Phased array transducer) (Option)

CWD GAIN

Cineloop

Support 2D, M, PW, CFM, CPA, DPD, TDI, CW

Simultaneous and independent review in Triplex mode

Cineloop auto/manual

Variable cine playback speed

User-define start and end frame of cine storage

User-define start and end frame of cine review

storage in hard disk and display in real-time modes

Slide show: slide show function

Storage

16G high speed memory(500G hard disk optional)

USB driver

Still images storage format: BMP

Still images export format: BMP, JPG

Cine loops storage format: CINE

Cine loops export format: AVI

Review

Image review Layout:1×1,2×2, 4×4

Image management

Archive

Patient info

Review report

Backup exam

Restore exam

Send exam

Delete exam

Patient view

Study view

Expand all

Collapse all

Select all

Ecografie parti moi Chison ECO6
TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Net weight of main unit (approx)
6.5 kg (no probe included)
Adapter Power supply voltage
AC100-240V 50/60Hz
Main system power input
19V 3.15A
Battery type
BT-2500 Li-ion 14.4V 4400mAh
Diagonal dimension
12 inch
Resolution
1024 x 768
Angle adjustable
0-30 o
C3-A convex probe, center frequency
3.5MHz
V6 -A micro-convex probe, center frequency
6.0MHz
L7M -A linear probe, center frequency
7.5MHz
MC3-A micro-convex probe, center frequency
3.0MHz
L7S-A linear probe, center frequency
7.5MHz
R7-A rectal probe, center frequency
7.5MHz
MC6-A micro-convex probe, center frequency
6.0MHz
P3-A Phased array transducer
3.0MHz
Duplex mode
B+CFM, B+CPA, B+DPD, B/M
Triplex mode
B+CFM+PW, B+CPA+PW, B+DPD+PW
High resolution
12 Inch LED display

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us