Earthquake Resistance portable Auto CPR machine EKONHS02
MODEL / EKONHS02In place of mechanical CPR, mechanical CPR devices can automatically deliver CPR strokes to continue blood circulation and oxygen supply of unresponsive victims. A large scale trial revealed one such automatic CPR device, called the AutoPulse, increased the survival rate of patients in need of CPR by 3.6%.
- 11、The pressure is not enough to alarm, the pressure depth is reduced automatically, and the manual
- 12、Electricity, according to the low voltage alarm, start the suspended function
- 14、Safety requirements refer to medical electrical appliances safety standard GB 9706.1-2007
Product Details
Quick Details
In place of mechanical CPR, mechanical CPR devices can automatically deliver CPR strokes to continue blood circulation and oxygen supply of unresponsive victims. A large scale trial revealed one such automatic CPR device, called the AutoPulse, increased the survival rate of patients in need of CPR by 3.6%.
Specifications
1、Pressing depth:30 ㎜~65 ㎜ adjustable,one type:5 ㎜,error:±2 ㎜; 2、Pressing release rate:1:1 ; 3、pressure relief valve:0.65Mpa;error:±0.12Mpa; 4、Pressure of gas road is no less than 1Mpa; 5、 Ventilation quanity:500ML no adjust,error:±10%; working pressure:≤816.4N ;

6、input power(DC):≤17W; AC:≤54W; 7、Press the ventilation ratio:30:2 continuously adjustable;,error:±1 time; 8、Pressing frequency: 100times/ min,110times/ min,120times/ min error:±1 time; 9、The fastness of fastening band fastness is not less than 100N; 10、The thickness range of patients was 155 to 305MM. 11、The pressure is not enough to alarm, the pressure depth is reduced automatically, and the manual recovery after air pressure recovery must be deep. 12、Electricity, according to the low voltage alarm, start the suspended function;

13、Default mode:Press the ventilation ratio: 30: 2,press depth 30mm,press frequence 100 pcs/min Ventilation quanity 500ML 14、Safety requirements refer to medical electrical appliances safety standard GB 9706.1-2007, electromagnetic compatibility standard YY05052012; 15、Earthquake Resistance 16、drop resistance 17、The enclosure protection level is IP55 (dustproof and water spray); 18、noise≤70dB ; 19、Working environment : a)Temperature:-20℃~55℃; b)Relative temperatur:10%~90%; c)Atmospheric pressure:500hPa~1060hPa.
Technical Specifications
Technical parameters from the currently available product information.
- 、Pressing depth
- 30 ㎜~65 ㎜ adjustable,one type:5 ㎜,error:±2 ㎜;
- 、Pressing release rate
- 1:1 ;
- 、pressure relief valve
- 0.65Mpa;error:±0.12Mpa;
- 、 Ventilation quanity
- 500ML no adjust,error:±10%;
- working pressure
- ≤816.4N ;
- 、input power(DC)
- ≤17W; AC:≤54W;
- 、Press the ventilation ratio
- 30:2 continuously adjustable;,error:±1 time;
- 、Pressing frequency
- 100times/ min,110times/ min,120times/ min error:±1 time
- 、The thickness range of patients was
- 155 to 305MM.
- 、Default mode
- Press the ventilation ratio: 30: 2,press depth 30mm,press frequence 100 pcs/min
- 、Working environment
- a)Temperature:-20℃~55℃;
- b)Relative temperatur
- 10%~90%
- c)Atmospheric pressure
- 500hPa~1060hPa.