EKONBI14 Infant incubator | newborn incubator
MODEL / EKONBI14Air mode control, set temperature and air temperature are displayed separately; Multiple failure alarm indications; RS-232 connector for data output.
- Air mode control, set temperature and air temperature are displayed separately
- Multiple failure alarm indications
- RS-232 connector for data output
- The temperature fluctuation range between incubator temperature and average incubator temperature(under stable temperature condition) : ≤0.5℃
Product Details
Quick Details
Brief Introduction
● Air mode control, set temperature and air temperature are displayed separately;
● Passive humidification;
● Multiple failure alarm indications;
● RS-232 connector for data output;
Specifications
EKONBI14 Infant incubator | newborn incubator
Brief Introduction
● Air mode control, set temperature and air temperature are displayed separately;
● Passive humidification;
● Multiple failure alarm indications;
● RS-232 connector for data output;
Standard Configuration
Hood, Base, Controller, I.V pole, Shelf.

EKONBI14 Infant incubator | newborn incubator
Specification
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA
Control Mode: Air mode control by micro-computer
Air temperature control range: 25℃-37℃ (override mode: 37℃-39℃ is optional)
The temperature fluctuation range between incubator temperature and average incubator temperature(under stable temperature condition): ≤0.5℃
Temperature uniformity: ≤0.8℃
Noise inside hood: ≤45dB(A)
Failure alarm: over temperature alarm, deviation alarm, sensor
failure alarm, fan motor alarm, power failure alarm, system alarm and so on.
EKONBI14 Infant incubator | newborn incubator
Optional Configuration
">37℃" override mode is optional, Baby mode, Disposable skin temperature sensor, SpO 2,
Configured with fixed neonate Bilirubin Phototherapy
Equipment which is EKONHD02 (Fixed model with blue LED)
Environmental temperature
Operating range: 20℃~30℃(Set temperature should
be 3℃ higher than the environment temperature)
Ambient air velocity: <0.3m/s
MSL TEAM picture
Welcome to medicalequipment-msl.com.
Technical Specifications
Technical parameters from the currently available product information.
- Power requirement
- AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA
- Control Mode
- Air mode control by micro-computer
- Air temperature control range
- 25℃-37℃ (override mode: 37℃-39℃ is optional)
- Temperature uniformity
- ≤0.8℃
- Noise inside hood
- ≤45dB(A)
- Failure alarm
- over temperature alarm, deviation alarm, sensor
- Operating range
- 20℃~30℃(Set temperature should
- Ambient air velocity
- <0.3m/s
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.