Incubators & Isolettes > Baby incubator

EKONBI14 Infant incubator | newborn incubator

MODEL / EKONBI14

Air mode control, set temperature and air temperature are displayed separately; Multiple failure alarm indications; RS-232 connector for data output.

  • Air mode control, set temperature and air temperature are displayed separately
  • Multiple failure alarm indications
  • RS-232 connector for data output
  • The temperature fluctuation range between incubator temperature and average incubator temperature(under stable temperature condition) : ≤0.5℃
PRODUCT OVERVIEW

Product Details

Quick Details

Brief Introduction

● Air mode control, set temperature and air temperature are displayed separately;

● Passive humidification;

● Multiple failure alarm indications;

● RS-232 connector for data output;

Specifications

EKONBI14 Infant incubator | newborn incubator

Brief Introduction

● Air mode control, set temperature and air temperature are displayed separately;

● Passive humidification;

● Multiple failure alarm indications;

● RS-232 connector for data output;

Standard Configuration

Hood, Base, Controller, I.V pole, Shelf.

Infant incubator

EKONBI14 Infant incubator | newborn incubator

Specification

Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA

Control Mode: Air mode control by micro-computer

Air temperature control range: 25℃-37℃ (override mode: 37℃-39℃ is optional)

The temperature fluctuation range between incubator temperature and average incubator temperature(under stable temperature condition): ≤0.5℃

Temperature uniformity: ≤0.8℃

Noise inside hood: ≤45dB(A)

Failure alarm: over temperature alarm, deviation alarm, sensor

failure alarm, fan motor alarm, power failure alarm, system alarm and so on.

EKONBI14 Infant incubator | newborn incubator

Optional Configuration

">37℃" override mode is optional, Baby mode, Disposable skin temperature sensor, SpO 2,

Configured with fixed neonate Bilirubin Phototherapy

Equipment which is EKONHD02 (Fixed model with blue LED)

Environmental temperature

Operating range: 20℃~30℃(Set temperature should

be 3℃ higher than the environment temperature)

Ambient air velocity: <0.3m/s

MSL TEAM picture

Welcome to medicalequipment-msl.com.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Power requirement
AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA
Control Mode
Air mode control by micro-computer
Air temperature control range
25℃-37℃ (override mode: 37℃-39℃ is optional)
Temperature uniformity
≤0.8℃
Noise inside hood
≤45dB(A)
Failure alarm
over temperature alarm, deviation alarm, sensor
Operating range
20℃~30℃(Set temperature should
Ambient air velocity
<0.3m/s

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us