MODEL / EKONBI17EKON Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods? arrive destination safely and quickly.
- Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance
- Set temperature, Air temperature, Baby temperature and Internal battery capacity can be displayed separately
- Multiple failure alarm indications
- ">37℃" temperature set function as optional configuration
Product Details
Quick Details
Brief Introduction
● Two temperature control modes: Air mode and Baby mode controlled by micro-computer;
● Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance;
● Set temperature, Air temperature, Baby temperature and Internal battery capacity can be displayed separately;
● Multiple failure alarm indications;
● ">37℃" temperature set function as optional configuration;
● Double wall acrylic glass hood with side door so that the bassinet can be pulled out from it;
● Passive humidification;
● The height of whole unit can be adjusted;
● Oxygen supply system;
● Observation lamp.
Specifications
EKONBI17 Infant incubator | neonatal incubator
Brief Introduction
● Two temperature control modes: Air mode and Baby mode controlled by micro-computer;
● Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance;
● Set temperature, Air temperature, Baby temperature and Internal battery capacity can be displayed separately;
● Multiple failure alarm indications;
● ">37℃" temperature set function as optional configuration;
● Double wall acrylic glass hood with side door so that the bassinet can be pulled out from it;
● Passive humidification;
● The height of whole unit can be adjusted;
● Oxygen supply system;
● Observation lamp.

EKONBI17 Infant incubator | neonatal incubator
Specification
AC power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 400VA
DC Power requirement: DC12V/10A or DC24V/6A
Control Mode: Air mode and Baby mode controlled by micro-computer
Air temperature control range: 25℃-37℃ (Override mode 37℃-38℃)
Baby temperature control range: 34℃-37℃ (Override mode 37-37.5℃)
Skin temperature sensor accuracy: ±0.2℃
The temperature fluctuation range between incubator temper-ature and average incubator temperature (under stable temper-ature condition): ≤1.0℃
Temperature uniformity: ≤1.5℃ (mattress is on the horizontal position)
Noise inside hood: ≤52 dB(A)
Failure alarm: over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm and so on.
Battery continuous working time: 90min (Set temperature is 36℃—
Ambient temperature is 15℃)
EKONBI17 Infant incubator | neonatal incubator
Optional Configuration
">37℃" override temperature mode, Disposable skin temperature sensor, Ambulance trolley
Environmental temperature
Operating range: 10℃~30℃(Set temperature should be 3℃ higher than the environment temperature)
Ambient air velocity: >0.3 m/s,<1.0m/s
MSL TEAM picture
Welcome to medicalequipment-msl.com.
Technical Specifications
Technical parameters from the currently available product information.
- Two temperature control modes
- Air mode and Baby mode controlled by micro-computer
- Use AC Power and DC Power alternatively, DC
- 12V or DC 24V Power on the ambulance
- AC power requirement
- AC220V-230V/50Hz or AC110-120V/50-60Hz, 400VA
- DC Power requirement
- DC12V/10A or DC24V/6A
- Control Mode
- Air mode and Baby mode controlled by micro-computer
- Air temperature control range
- 25℃-37℃ (Override mode 37℃-38℃)
- Baby temperature control range
- 34℃-37℃ (Override mode 37-37.5℃)
- Skin temperature sensor accuracy
- ±0.2℃
- Temperature uniformity
- ≤1.5℃ (mattress is on the horizontal position)
- Noise inside hood
- ≤52 dB(A)
- Failure alarm
- over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm and so on.
- Battery continuous working time
- 90min (Set temperature is 36℃—
- Operating range
- 10℃~30℃(Set temperature should be 3℃ higher than the environment temperature)
- Ambient air velocity
- >0.3 m/s,<1.0m/s
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.