EKONEA05 Electrolyte Analyzer for Lab Test
MODEL / EKONEA05Full numeric keyboard makes selection function is faster, lifetime is longer; Patented against-counter integrated reagents pack is designed to care operator and protect environment, it is safety, easy to change and replace; Low reagent consumption.
- Full numeric keyboard makes selection function is faster, lifetime is longer.
- Patented against-counter integrated reagents pack is designed to care operator and protect environment, it is safety, easy to change and replace
- Low reagent consumption
- Standby mode will save more reagent
Product Details
Quick Details
Our advantage
● Electrode
Electrode free, new technology MBT( multi biosensor technology), fully maintenance free
● LCD display
A green backlight 128*64 multi-line display makes operator could see clearly.
● Membrane keyboard
Full numeric keyboard makes selection function is faster, lifetime is longer.
● Reagents Pack
Patented against-counter integrated reagents pack is designed to care operator and protect environment, it is safety, easy to change and replace
● Low reagent consumption
400 samples can be tested with only one reagent pack if consecutive testing.
● Standby mode will save more reagent
Specifications
EKONEA05 Electrolyte Analyzer for Lab Test
Intended Use: The Na +, K +, Cl -,Ca 2+ methods on the CBS Electrolyte Analyzer system are in Vitro diagnostic tests intended for the quantitative measurement of Sodium, Potassium, Ionized Calcium and Chloride in serum and Urine. They are also intended for the quantitative measurement of Na +,K +, Cl -, Ca 2+ in diluted urine.
Summary: The Sodium, Potassium, Ionized Calcium and Chloride methods use direct sensing Multi-Biosensor Module (MBM) to develop an electrical potential proportional to the activity of each specific ion in the sample.

EKONEA05 Electrolyte Analyzer for Lab Test
Our advantage
● Electrode
Electrode free, new technology MBT( multi biosensor technology), fully maintenance free
● LCD display
A green backlight 128*64 multi-line display makes operator could see clearly.
● Membrane keyboard
Full numeric keyboard makes selection function is faster, lifetime is longer.
● Reagents Pack
Patented against-counter integrated reagents pack is designed to care operator and protect environment, it is safety, easy to change and replace
● Low reagent consumption
400 samples can be tested with only one reagent pack if consecutive testing.
● Standby mode will save more reagent

EKONEA05 Electrolyte Analyzer for Lab Test
Principles of Procedure: CBS multi-sensor has four ion selective electrodes ( ISE) measuring ion concentration of sodium, potassium, Ionized Calcium and chloride in sample. Another chloride electrode is integrated in cartridge as a reference electrode. Each ion selective membrane undergoes a specific reaction with the ion contained in the sample. The membrane reacts to the difference of potential of sample and the standard solution A and calculation. Then ion concentration in the sample is determined.
Installation: Open the bag, put module into the box, close the cover. Installation details please refer to "EKONEA05 Electrolyte Analyzer Manual."
Sample Collection: The samples collection of serum and urine by routine method can be used in CBS-Multi-sensor.
1. Plasma samples by rapid centrifugation of heparinized whole blood, were isolated from the red blood cells, and seal the sample in a test tube;
2. Serum samples collected in a blood collection cup, 30 minutes and centrifuged to remove serum clot, sealed tube;
3. Urine samples were collected at random in accordance with statutes or 24-hour urine.

Specification
● Test parameter:
K、Na、Cl、Ca、Ph
● 3 testing modes:
whole blood,urine and serum
● Test speed:
80 samples per hour
● LCD display, Membrane keyboard, Built-in thermal printer
● up to 1000 sample results can be stored
conditions of use: At room temperature of 15~30 C, the service life is no less than 600 samples, or 10 samples per day, the number of days used is no less than 20 days.



MSL TEAM picture
Welcome to medicalequipment-msl.com.
Technical Specifications
Technical parameters from the currently available product information.
- Intended Use
- The Na+, K+, Cl- ,Ca2+ methods on the CBS Electrolyte Analyzer system are in Vitro diagnostic tests intended for the quantitative measurement of Sodium, Potassium, Ionized Calcium and Chloride in serum and Urine. They are also intended for the quantitative measurement of Na+ ,K+, Cl- , Ca2+ in diluted urine.
- Summary
- The Sodium, Potassium, Ionized Calcium and Chloride methods use direct sensing Multi-Biosensor Module (MBM) to develop an electrical potential proportional to the activity of each specific ion in the sample.
- Principles of Procedure
- CBS multi-sensor has four ion selective electrodes ( ISE) measuring ion concentration of sodium, potassium, Ionized Calcium and chloride in sample. Another chloride electrode is integrated in cartridge as a reference electrode. Each ion selective membrane undergoes a specific reaction with the ion contained in the sample. The membrane reacts to the difference of potential of sample and the standard solution A and calculation. Then ion concentration in the sample is determined.
- Installation
- Open the bag, put module into the box, close the cover . Installation details please refer to "EKONEA05 Electrolyte Analyzer Manual."
- Sample Collection
- The samples collection of serum and urine by routine method can be used in CBS-Multi-sensor.
- Expiration
- Valid for 1 year, after opening the package is valid for 1 month
- conditions of use
- At room temperature of 15~30 C, the service life is no less than 600 samples, or 10 samples per day, the number of days used is no less than 20 days.
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.