Surgery

EKONEK12 Six Working Modes Electrosurgical Generator

MODEL / EKONEK12

Max 350W Electrosurgical Generator, with mono-polar and bipolar function; Wide clinical applications, such as the general surgery, thoracic surgery, orthopedic surgery, cardiology, gynecology, urology(under water TUR), oncology, neurosurgery, etc; Microprocessor controlled, digital display. With audible and visual indicators and errors codes during the process of outputting.

  • Max 350W Electrosurgical Generator, with mono-polar and bipolar function.
  • Wide clinical applications, such as the general surgery, thoracic surgery, orthopedic surgery, cardiology, gynecology, urology(under water TUR), oncology, neurosurgery, etc.
  • Microprocessor controlled, digital display. With audible and visual indicators and errors codes during the process of outputting.
  • Return Electrode Monitoring system and Power Peak System, minimizing the risk of tissue damage.
PRODUCT OVERVIEW

Product Details

Quick Details

★Max 350W Electrosurgical Generator, with mono-polar and bipolar function.

★Six working modes: pure cut, blend1, blend2, forced coag, soft coag, bipolar coag.

★Wide clinical applications, such as the general surgery, thoracic surgery, orthopedic surgery, cardiology, gynecology, urology(under water TUR), oncology, neurosurgery, etc.

★Microprocessor controlled, digital display. With audible and visual indicators and errors codes during the process of outputting.

★Return Electrode Monitoring system and Power Peak System, minimizing the risk of tissue damage.

★Both hand and foot controlled.

★Separate power display and outlet socket for mono-polar cut, mono-polar coag, bipolar cut and bipolar coag, each output can be individually configured.

★The unit always remember the last setting when it turned off.

★Remote control function. The surgeon can adjust the outputs by power control ESU pencil.

★The ESU unit can be connected with laparoscope and endoscope, etc.

★Protection against over-voltage and over-current.

★Defibrillation protected.

★Mounted on a 4 wheels cart(optional).

Meets the requirements of international safety standards EN60601-1 and EN60601-2.

Specifications

EKONEK12 Six Working Modes Electrosurgical Generator

electrosurgical devices

EKONEK12 Six Working Modes Electrosurgical Generator

★Max 350W Electrosurgical Generator, with mono-polar and bipolar function.

★Six working modes: pure cut, blend1, blend2, forced coag, soft coag, bipolar coag.

★Wide clinical applications, such as the general surgery, thoracic surgery, orthopedic surgery, cardiology, gynecology, urology(under water TUR), oncology, neurosurgery, etc.

★Microprocessor controlled, digital display. With audible and visual indicators and errors codes during the process of outputting.

★Return Electrode Monitoring system and Power Peak System, minimizing the risk of tissue damage.

★Both hand and foot controlled.

★Separate power display and outlet socket for mono-polar cut, mono-polar coag, bipolar cut and bipolar coag, each output can be individually configured.

★The unit always remember the last setting when it turned off.

★Remote control function. The surgeon can adjust the outputs by power control ESU pencil.

★The ESU unit can be connected with laparoscope and endoscope, etc.

★Protection against over-voltage and over-current.

★Defibrillation protected.

★Mounted on a 4 wheels cart(optional).

Meets the requirements of international safety standards EN60601-1 and EN60601-2.

electrosurgical devices

EKONEK12 Six Working Modes Electrosurgical Generator

Technical Specifications

Power: 220V±22V, 50Hz±1Hz(110V±11V, 60Hz)

Operating frequency: 512KHz

Power rating: 1100VA±10%

Six working modes:

◆Mono-polar Cut

a) Pure cut:1W~350W( Load 800Ω)

b) Blend1:1W~200W(Load 800Ω)

c) Blend2:1W~250W(Load 800Ω)

◆Mono-polar Coag

d) Spray Coag:1W~80W( Load 800Ω)

e) Soft Coag:1W~120W( Load 800Ω)

◆Bipolar

f) Bipolar Coagulation: 1W~70W( Load 200Ω)

◆Power Consumption: ≤1100VA

Configuration Sheet

Electrosurgical Pencil 5pcs

Electrosurgical Pad 10pcs

Electrosurgical pad cable 1pcs

Footswitch 1set

Bipolar Forceps 1pcs

Bipolar forceps cable 1pcs

electrosurgical devices

MSL TEAM picture

Welcome to medicalequipment-msl.com,If you have any demand in ultrasound machine.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Six working modes
pure cut, blend1, blend2, forced coag, soft coag, bipolar coag.
Power
220V±22V, 50Hz±1Hz(110V±11V, 60Hz)
Operating frequency
512KHz
Power rating
1100VA±10%
a) Pure cut
1W~350W( Load 800Ω)
b) Blend1
1W~200W(Load 800Ω)
c) Blend2
1W~250W(Load 800Ω)
d) Spray Coag
1W~80W( Load 800Ω)
e) Soft Coag
1W~120W( Load 800Ω)
f) Bipolar Coagulation
1W~70W( Load 200Ω)
Power Consumption
≤1100VA

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us