Face lifting skin tightening machine with RF & Integrated head EKONRF03

MODEL / EKONRF03

Applicable parts: integrated head, chin, cheek, eyes, forehead, abdomen, back, waist, arms, thighs, buttocks and other parts. RF gun: neck, chin, cheek, eyes, forehead, abdomen, back, waist, arms, thighs, legs and other parts.

  • We provide lifetime maintenance and technical support.
  • Hifu wrinkle removal EKONHF02 lipo hifu EKONHF06 Portable hifu EKONHF07
  • Portable vaginal hifu EKONHF10 liposonic+hifu EKONHF15 Two cryo cavitation lipo laser rf EKONCY06
  • EKON Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods? arrive destination safely and quickly.
PRODUCT OVERVIEW

Product Details

Quick Details

Applicable parts: integrated head, chin, cheek, eyes, forehead, abdomen, back, waist, arms, thighs, buttocks and other parts. RF gun: neck, chin, cheek, eyes, forehead, abdomen, back, waist, arms, thighs, legs and other parts.

Specifications

Face lifting skin tightening machine with RF & Integrated head EKONRF03

Face lifting skin tightening machine

Face lifting skin tightening machine Product Overview

We are so appreciated you select our newest beauty apparatus for facial wrinkle reduction, and Thermal body&face lifting is the new gener- ation of non-invasive skin firming and perfecting technology. Thermal body&face lifting is a non-invasive beauty apparatus for facelift that has passed China's Compliance Certification and CE Certification. Thermal body&face lifting Focus RF is the new generation of RF firming technology, and the accurate action on surface layer, superficial layer, middle layer and deep layer to achieve the purpose of wrinkles reduc- ing, tightening and beautifying.

Before using the beauty instrument, please read this manual carefully and strictly adhere to the guidelines.

Face lifting skin tightening machine Instrumental Advantage

best rf skin tightening face lifting

"Thermal body&face lifting", a miracle instrument to make facelift without any surgical operation, which can effectively reduce the wrinkles, awaken the skin elasticity, lift the soft tissue structure, improve to firm the face and intensify the rejuvenation effect on the face, honored as "a spring of younger".

Face lifting skin tightening machine Operating Procedures

Step1:Clean up the operation part firstly.

Step2:Press the circular switch key at the top of the screen to open the display screen.

Step3:A small interface will occur on the display after opening the display (Figure 2), the speaker icon is the sound control. Click the speaker icon slightly, the speak- er will display X, and X represents a closed sound of the instrument. Click ENTER to enter the main interface.

Step4:Two options are available after entering the main interface (interface figure). UNILARGE represents RF head operation interface. BIPOLAR represents to enter the integrated head (including three functions, i.e., negative pre ssu re, refri g erati on an d rad i o frequency) operation interface.

Step5:We click BIPOLAR to enter the integrated head operation interface (as shown in figure).

Step6:Then adjust the operation time, set the face operation time as 60min, and body operation time as 90 min.

Step7:Click on the screen to select the energy adjustment, slightly click arrow to adjust the energy strength as 40, then click to open refrigeration and RF, click to open the negative pressure function. Finally click, four options are available for MODE, 1 represents that the operating head absorbs for 1s and releases for 1s, 2 represents that the operating head absorbs for 2s releases for 1 and 3 represents that the operating head absorbs for 3s and releases for 1s (in the operation process, the more time the operation head absorbs, the stronger feel it represents, vice versa. The mode should be selected based on the user's feeling. When the instrument is applied to the body, it is suggested to select the mode with the longest time for the body operation).

rf skin tightening face lift RF machine

Face lifting skin tightening machine Use Contraindication

People with the following symptoms shall be cautious when using the instrument and ask for advices from the doctor or professional; the details are as follows:

In case the operation part has been filled with artificial fillers, such filled part shall be avoided when operating the instrument.

The customer should tell to doctor whether she/he has injected hyaluronic acid or collagen within half year;

The customer shall not wear any metal articles in the operation;

People with heart diseases or wearing the pace maker are not suggested to conduct any operation. The customer is not suggested to make up on the day accepting the operation, or the face should be cleaned up before the operation;

The operation shall not be operated if the female is in the period;

In the operation, the detector shall not be operated on the position with wound or purulent acne, within orbital bones or Adam's apple;

This instrument is not suitable for the patient allergic to metal.

Although sufficient evidence is not available to certify that this instrument can influence the patients with tumor and active skin disease, it is not suggested that such patient to use this instrument. Although direct evidence is not available to certify that this instrument has any effect on the pregnant, it is not suggested the pregnant to use this instrument.

Although it is not certified that the ultrasonic wave may result in osteoporosis of the rib, it is not suggested to operate the instrument on the rib.

If the face is in an allergic period, this instrument shall not be operated within one week after the completion of the allergic period.

The lowest level of energy shall be adopted when using this beautifying instrument, and the energy can be adjusted and increased gradually based on their actual feelings, until they have the most comfortable feeling. It is forbidden to open the energy to the largest level, the bearing energy of each person is not the same, thus the energy strength will be different in specific operation, and if the instrument is started with the highest energy level, it may injure the skin.

People not suitable to use the instrument: 1. Those do not carry out any care and maintenance; 2. Those have a sensitive and extremely dry skin; 3. Those have pustules and acne. After the opera- tion, detoxification phenomena may occur on the face, such as pimple, acne, acturc discascs and rubedo, which are normal. For such conditions, maintenance and hydrating mask will be effective.

Note: This instrument should be matched with our dedicated medium instead of other gel or essential oil when using; any problem incurred due to using other mediums will be considered as individual responsibility.

Skin Tightening

Notes to Operate Thermal body&face lifting

Hot water shall not be used to wash face within 3 days; (warm or cold water is available) The moisturizing and sun protection of the operated position shall be strengthened;

Hot spring shall not be used within 3 days;

Make-up shall not be conducted within one day after the operation, light make-up is available after one day, and heavy make-up shall not be conducted after 4 days;

It is suggested to use 4 masks at least, and drink water not less than 2000cc (8 cups of water). Spicy food shall be avoided as much as possible, smoking, drinking and staying up shall be forbid- den, fruit and vegetables shall be eaten as much as possible, and the meals shall be light.

It is not suggested to carry out strenuous exercises at the current day using the instrument.

RF & Integrated head EKONRF03

Face lifting skin tightening machine Equipment Maintenance

Please clean the instrument with clean water and stored properly after each operation.

Plug with pin is a must before using the instrument, and it must ensure that the power socket of the instrument is really grounded.

Ensure the instrument voltage is suitable. We suggest the user to increase the voltage-stable power matching with the power if the local power voltage is not stable.

The instrument can neither be placed in the damp place or around water source; nor be exposed to direct sunshine.

The instrument cannot be close to the strong heat source, if so, it shall affect the service life and normal use of the instrument.

The medium, such as water, oil, etc. cannot leak in the instrument, and the instrument cannot be knocked, thrown or heavy falls in case of damage the instrument.

Please clean the detector timely after the operation and cut off the power supply.

The warranty period is one year. The instrument is maintained and replaces components for free under the precondition of normal use during the warranty period.

We provide lifetime maintenance and technical support.

The instrument shall not be cleaned and wiped with any articles containing ethyl alcohol.

Face lifting skin tightening machine EKONRF03

Beauty equipment supply store hot sale spa equipment

MSL TEAM picture

Welcome to medicalequipment-msl.com,If you have any demand in ultrasound machine.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

980NM Spider vein removal EKONVR0Yag Laser Tattoo removal EKONYL02OPT SHR Machine EKONHR02
Hifu wrinkle removal EKONHF02lipo hifu EKONHF06Portable hifu EKONHF07
Portable vaginal hifu EKONHF10liposonic+hifu EKONHF15Two cryo cavitation lipo laser rf EKONCY06
Shockwave therapy EKONST01Fat freezing machine EKONCY01laser hair removal machine EKONDL01
Hydra facial Skin Machine EKONDM04Rf body slimming EKONDM05-2Nd: YAG skin whitening EKONPL02
ipl hair removal machine EKONOL01RF infrared slimming machine EKONVS03painless hair removal EKONDL05

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us