1. Physical Characteristic Size: 130mm (Length) ×100mm (Width) ×36 (Height) mm Weight: About 250g (including batteries) 2. Display: 44.5mm×23mm LCD display 3. Backlight: The two statuses can be alternated: turn off/on the backlight. 4. Suitable Using Range: Suitable for use after the 16th week of pregnancy
Specifications
Features of Pocket Fetus Doppler EKONJB04:
1.Battery status indicator 2.Low power inspection of the battery 3.Built-in speaker 4.Output for earphone 5.The probe can be changeable 6.Probe inspection 7.Backlight 8.Auto shut off 9.Two pieces of standard 1.5V alkaline batteries available which can work no less than 10 hours.


Specifications of Pocket Fetus Doppler EKONJB04: 1. Physical Characteristic Size: 130mm (Length) ×100mm (Width) ×36 (Height) mm Weight: About 250g (including batteries) 2. Display: 44.5mm×23mm LCD display 3. Backlight: The two statuses can be alternated: turn off/on the backlight. 4. Suitable Using Range: Suitable for use after the 16th week of pregnancy 5. FHR Performance FHR Measuring Range: 50~210BPM (BPM: beat per minute) Resolution: 1bpm Accuracy: ±2bpm 6. Power consumption: ≤0.7W 7. Auto Shut-off: After 1 minute no signal, power off automatically. 8. Battery Type Recommended: Two pieces of 1.5 V DC batteries (SIZE AA LR6). 9. Ultrasonic Probe:


Working Frequency: 3.0MHz±10% Working Mode: Continuous wave Doppler Overall sensitivity:> 90dB Spatial-peak temporal-peak acoustic pressure: <0.1MPa Output power: <20mW

Technical Specifications
Technical parameters from the currently available product information.
- Display
- 44.5mm×23mm LCD display
- Suitable Using Range
- Suitable for use after the 16th week of pregnancy
- FHR Measuring Range
- 50~210BPM (BPM: beat per minute)
- Resolution
- 1bpm
- Accuracy
- ±2bpm
- Power consumption
- ≤0.7W
- Auto Shut-off
- After 1 minute no signal, power off automatically.
- Battery Type Recommended
- Two pieces of 1.5 V DC batteries (SIZE AA LR6).
- Working Frequency
- 3.0MHz±10%
- Working Mode
- Continuous wave Doppler
- Overall sensitivity
- > 90dB
- Spatial-peak temporal-peak acoustic pressure
- <0.1MPa
- Output power
- <20mW