Lab Equipment

Hot Sale Quantitative Electrolyte Analyzer EKONEA06

MODEL / EKONEA06

Full numeric keyboard makes selection function is faster, lifetime is longer; Patented against-counter integrated reagents pack is designed to care operator and protect environment, it is safety, easy to change and replace; Low reagent consumption.

  • Full numeric keyboard makes selection function is faster, lifetime is longer.
  • Patented against-counter integrated reagents pack is designed to care operator and protect environment, it is safety, easy to change and replace
  • Low reagent consumption
  • Standby mode will save more reagent
PRODUCT OVERVIEW

Product Details

Quick Details

Our advantage

● Electrode

Electrode free, new technology MBT( multi biosensor technology), fully maintenance free

● LCD display

A green backlight 128*64 multi-line display makes operator could see clearly.

● Membrane keyboard

Full numeric keyboard makes selection function is faster, lifetime is longer.

● Reagents Pack

Patented against-counter integrated reagents pack is designed to care operator and protect environment, it is safety, easy to change and replace

● Low reagent consumption

400 samples can be tested with only one reagent pack if consecutive testing.

● Standby mode will save more reagent

Specifications

Hot Sale Quantitative Electrolyte Analyzer EKONEA06

Intended Use: The Na +, K +, Cl -,Ca 2+ methods on the CBS Electrolyte Analyzer system are in Vitro diagnostic tests intended for the quantitative measurement of Sodium, Potassium, Ionized Calcium and Chloride in serum and Urine. They are also intended for the quantitative measurement of Na +,K +, Cl -, Ca 2+ in diluted urine.

Summary: The Sodium, Potassium, Ionized Calcium and Chloride methods use direct sensing Multi-Biosensor Module (MBM) to develop an electrical potential proportional to the activity of each specific ion in the sample.

uses of electrolytes

Hot Sale Quantitative Electrolyte Analyzer EKONEA06

Our advantage

● Electrode

Electrode free, new technology MBT( multi biosensor technology), fully maintenance free

● LCD display

A green backlight 128*64 multi-line display makes operator could see clearly.

● Membrane keyboard

Full numeric keyboard makes selection function is faster, lifetime is longer.

● Reagents Pack

Patented against-counter integrated reagents pack is designed to care operator and protect environment, it is safety, easy to change and replace

● Low reagent consumption

400 samples can be tested with only one reagent pack if consecutive testing.

● Standby mode will save more reagent

uses of electrolytes

Hot Sale Quantitative Electrolyte Analyzer EKONEA06

Principles of Procedure: CBS multi-sensor has four ion selective electrodes ( ISE) measuring ion concentration of sodium, potassium, Ionized Calcium and chloride in sample. Another chloride electrode is integrated in cartridge as a reference electrode. Each ion selective membrane undergoes a specific reaction with the ion contained in the sample. The membrane reacts to the difference of potential of sample and the standard solution A and calculation. Then ion concentration in the sample is determined.

Installation: Open the bag, put module into the box, close the cover. Installation details please refer to "EKONEA06 Electrolyte Analyzer Manual."

Sample Collection: The samples collection of serum and urine by routine method can be used in CBS-Multi-sensor.

1. Plasma samples by rapid centrifugation of heparinized whole blood, were isolated from the red blood cells, and seal the sample in a test tube;

2. Serum samples collected in a blood collection cup, 30 minutes and centrifuged to remove serum clot, sealed tube;

3. Urine samples were collected at random in accordance with statutes or 24-hour urine.

electrolyte labs

Specification

● Test parameter:

K、Na、Cl、Ca、Ph、TCO2

● 3 testing modes:

whole blood,urine and serum

● Test speed:

80 samples per hour( 40 T/h with TCO2)

● LCD display, Membrane keyboard, Built-in thermal printer

● up to 1000 sample results can be stored

Use Limitations: the serum, plasma, urine, cerebrospinal fluid, pleural effusion, ascites, electrolyte ions (potassium, sodium, chloride, calcium).

Whole blood specimens cannot be analyzed. The interaction of acidifying reagent and whole blood sample forms precipitates which may block the flow lines.

Storage condition: Advises to store the multi-biosensor at room temperature, the period of validity is 12 months.

conditions of use: At room temperature of 15~30 C, the service life is no less than 600 samples, or 10 samples per day, the number of days used is no less than 20 days.

electrolytes test
electrolyte analyser

MSL TEAM picture

Welcome to medicalequipment-msl.com.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Intended Use
The Na+, K+, Cl- ,Ca2+ methods on the CBS Electrolyte Analyzer system are in Vitro diagnostic tests intended for the quantitative measurement of Sodium, Potassium, Ionized Calcium and Chloride in serum and Urine. They are also intended for the quantitative measurement of Na+ ,K+, Cl- , Ca2+ in diluted urine.
Summary
The Sodium, Potassium, Ionized Calcium and Chloride methods use direct sensing Multi-Biosensor Module (MBM) to develop an electrical potential proportional to the activity of each specific ion in the sample.
Principles of Procedure
CBS multi-sensor has four ion selective electrodes ( ISE) measuring ion concentration of sodium, potassium, Ionized Calcium and chloride in sample. Another chloride electrode is integrated in cartridge as a reference electrode. Each ion selective membrane undergoes a specific reaction with the ion contained in the sample. The membrane reacts to the difference of potential of sample and the standard solution A and calculation. Then ion concentration in the sample is determined.
Installation
Open the bag, put module into the box, close the cover . Installation details please refer to "EKONEA06 Electrolyte Analyzer Manual."
Sample Collection
The samples collection of serum and urine by routine method can be used in CBS-Multi-sensor.
Precautions
Module only for in vitro diagnostic. from the cold storage environment should keep 1 hour at room temperature before installation. Used Modules are Medical waste maybe contain human body fluids with infectious agents. care to avoid skin contact and ingestion. should be properly handled in accordance with relevant rules and regulations.
Use Limitations
the serum, plasma, urine, cerebrospinal fluid, pleural effusion, ascites, electrolyte ions (potassium, sodium, chloride, calcium).
Storage condition
Advises to store the multi-biosensor at room temperature, the period of validity is 12 months.
Expiration
Valid for 1 year, after opening the package is valid for 1 month
conditions of use
At room temperature of 15~30 C, the service life is no less than 600 samples, or 10 samples per day, the number of days used is no less than 20 days.

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.