Surgery > Oximeter machine

Innovo pulse oximeter device EKONXY37

MODEL / EKONXY37

SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is +/-4%, pulse rate error is +/-2 bpm or +/-2% (select larger).

  • Safety Type: Interior Battery, BF Type
PRODUCT OVERVIEW

Product Details

Quick Details

Integrated with Sp o2 probe and processing display module Small in volume, light in weight and convenient in carrying Operation of the product is simple, low power consumption SpO 2 value display

Specifications

Innovo pulse oximeter device EKONXY37

*Integrated with Sp o2 probe and processing display module *Small in volume, light in weight and convenient in carrying *Operation of the product is simple, low power consumption *SpO 2 value display

Innovo pulse oximeter device EKONXY37

Innovo pulse oximeter device EKONXY37 *Pulse rate value display, bar graph display *Pulse waveform display *The display mode can be changed *Screen brightness can be changed *Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage *Automatically power off function: when the device is under the state of measuring interface. it will automatically power off within 5 seconds if the finger falls out of probe *Display format can be saved after power off

Innovo pulse oximeter device EKONXY37

Innovo pulse oximeter device EKONXY37 Main performance Display Mode: 0.96"Dual-color OLED display(blue and yellow) Screen Resolution: 128*64 SpO 2 Measuring Range: 0%~100%, (the resolution is 1%). Accuracy: 70%~100%: +/-2%,Below 70% unspecified. PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm) Accuracy: +/-2bpm or +/-2% (select larger) Measurement Performance in Weak Filling Condition: SpO 2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO 2 error is +/-4%, pulse rate error is +/-2 bpm or +/-2% (select larger). Resistance to Surrounding Light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than +/-1%. Power Consumption: less than30mA

Innovo pulse oximeter device EKONXY37

Voltage: DC 3.0V Power Supply: 1.5V (AAA size) alkaline batteries * 2 Battery Working Hour: The minimum continually work time is 20 hours, theoretical number is 36 hours. Safety Type: Interior Battery, BF Type

Innovo pulse oximeter device EKONXY37 Accessories Sell in standard: *A hanging rope *A user manual

Innovo pulse oximeter device EKONXY37

Physical Identity Dimension: 57(L) * 31(W) * 32(H) mm Weight: About 50g (with the batteries)

Innovo pulse oximeter device EKONXY37 Qualification Passed FDA and CE

Innovo pulse oximeter device EKONXY37
TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

*Low-voltage indication
low-voltage indicator appears before working abnormally which is due to low-voltage
*Automatically power off function
when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe
Display Mode
0.96"Dual-color OLED display(blue and yellow)
Screen Resolution
128*64
SpO2 Measuring Range
0%~100%, (the resolution is 1%).
Accuracy
70%~100%: +/-2% ,Below 70% unspecified.
PR Measuring Range
30bpm~250bpm, (the resolution is 1bpm)
Resistance to Surrounding Light
The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than +/-1%.
Power Consumption
less than30mA
Voltage
DC 3.0V
Power Supply
1.5V (AAA size) alkaline batteries * 2
Battery Working Hour
The minimum continually work time is 20 hours, theoretical number is 36 hours.
Dimension
57(L) * 31(W) * 32(H) mm

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.