International Pioneering Microarray Chemiluminescence Biochip Detection System EKONCM05
MODEL / EKONCM05Low cost:Routine inspection items integrated in a chip, forming a " lab on chip"and saving raw materials.
- Loading system:Teflon coated S/R probe with liquid level detection function
- High Accuracy:Mainstream chemiluminescence method ensuring high sensitivity, wide linearity and excellent repeatability.
- High Detection Rate:Research achievement of"863” program, optimized combination of indices and coordinated determination to reduce misdiagnosis and missed diagnosis.
- Automation:Fully-automatic devices saving manual operation and avoiding man-made error.
Product Details
Quick Details
System Type:2nd Generation of EKONCM05 Principles:Microarray Chemiluminescent Immunoassay Reagents:Sunlant reagent test kit Speed:720 tests/hour Operation mode:Fully automatic load sample and biochip, random, batch and emergency priority Sample position:60 positions. Continuous loading is allowed during the testing process and Emergency priority Reagent position:18 positions Loading system:Teflon coated S/R probe with liquid level detection function
Specifications
Technical Parameters:
System Type:2nd Generation of EKONCM05 Principles:Microarray Chemiluminescent Immunoassay Reagents:Sunlant reagent test kit Speed:720 tests/hour Operation mode:Fully automatic load sample and biochip, random, batch and emergency priority Sample position:60 positions. Continuous loading is allowed during the testing process and Emergency priority Reagent position:18 positions Loading system:Teflon coated S/R probe with liquid level detection function Detection system: CCD with 2 million 800 thousand pixels Calibration method:5 point calibration Temperature:30±0.1℃ Precision:The CV of the test should be ≤5% Operation System:Windows 7 Dimensions:1510 mm×910 mm×1150 mm Weight:310 kg Networking:Can be linked with LIS system of the hospital through COM or network card Environment:Supply Voltage: 220V±22V,50Hz±1Hz, 1500VA; Temperature: 20℃~26℃ Air pressure: 85 kPa~106 kPa



Advantages:
1.High Throughput:Integrated with 56 lattices,each of which are able to provide finite information 2.Low cost:Routine inspection items integrated in a chip, forming a " lab on chip"and saving raw materials. 3.High Efficiency:Only 180ul blood is required for testing of all combined indices. 4.High Accuracy:Mainstream chemiluminescence method ensuring high sensitivity, wide linearity and excellent repeatability. 5.High Detection Rate:Research achievement of"863” program, optimized combination of indices and coordinated determination to reduce misdiagnosis and missed diagnosis. 6.Automation:Fully-automatic devices saving manual operation and avoiding man-made error.


Technical Specifications
Technical parameters from the currently available product information.
- System Type
- 2nd Generation of EKONCM05
- Principles
- Microarray Chemiluminescent Immunoassay
- Speed
- 720 tests/hour
- Operation mode
- Fully automatic load sample and biochip, random, batch and emergency priority
- Sample position
- 60 positions. Continuous loading is allowed during the testing process and Emergency priority
- Reagent position
- 18 positions
- Detection system
- CCD with 2 million 800 thousand pixels
- Calibration method
- 5 point calibration
- Temperature
- 30±0.1℃
- Precision
- The CV of the test should be ≤5%
- Operation System
- Windows 7
- Dimensions
- 1510 mm×910 mm×1150 mm
- Networking
- Can be linked with LIS system of the hospital through COM or network card
- Environment
- Supply Voltage: 220V±22V,50Hz±1Hz, 1500VA;
- Air pressure
- 85 kPa~106 kPa
- High Throughput
- Integrated with 56 lattices,each of which are able to provide finite information
- Low cost
- Routine inspection items integrated in a chip, forming a " lab on chip"and saving raw materials.
- High Efficiency
- Only 180ul blood is required for testing of all combined indices.
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.