Other
Medical Waste Incinerator for Hospital EKONWI300B
MODEL / EKONWI300BMedical Waste Incinerator for Hospital EKONWI300B. Welcome to medicalequipment-EKON.com.
- Combustion-support combustion machines
PRODUCT OVERVIEW
Product Details
Quick Details
Specifications
Medical Waste Incinerator for Hospital EKONWI300B

Medical Waste Incinerator for Hospital EKONWI300B

standard configuration
Medical Waste Incinerator for Hospital EKONWI300B




MSL TEAM picture
Welcome to medicalequipment-msl.com.
TECHNICAL DATA
Technical Specifications
Technical parameters from the currently available product information.
| Applicable hospital size (number of beds) | 300-500beds |
| Burning Ability | 200-300㎏/ times (daily incineration3-6 times) |
| Size of the Burner | 2.2m×1.4m×3.8m |
| Applicable hospital size (number of beds) | 300-500beds |
| Burning Ability | 200-300㎏/ times (daily incineration3-6 times) |
| Size of the Burner | 2.2m×1.4m×3.8m |
| Volume of the Burner | Gasification room2.4m3,secondary bumingroom1.2m3,drift a long buming a room0.16m3 |
| Size of the filling entrance | 900㎜×1100㎜ |
| Chimney | Height 10m out-radius¢400mm |
| Blower | Power 1.1kw |
| Combustion-support combustion machines | Power 0.22kw,fuelconsumption7-14kg/h |
| Re-burning machine | Power 0.37kw,fuelconsumption10-20kg/h |
| Running voltage | 220V or380V |
| Weight | About 9500kg |
| No | Name | Amount | Specifications | Notes |
| 1 | Incinerator | 1 | A3 steel refractories | Main part |
| 2 | The 2 combustion chamber and the combustion chamber mixed | 1 | A3 steel refractories | Installed in Main body |
| 3 | Electric box | 1 | Main body | |
| 4 | Fluegas purification system | 1 | A3 steel refractories | Installed in Main body |
| 5 | Combustion burner | 1 | BTL-10(Italy) | Main body |
| 6 | Reburning burner | 1 | BTL-26G(Italy) | Main body |
| 7 | blower | 1 | 1100W/220V/380V | Main body |
| 8 | Ash rake | 1 | ¢200mm×3000mm | |
| 9 | Pump | 1 | Main body | |
| 10 | fuel tank | 1 | Main body | |
| 11 | fuel tank bracket | 1 | ¢500mm×2200mm | |
| 12 | Chimney | 2 | ¢400mm×5000mm ¢400mm×5000mm | |
| 13 | Filter switch | 5 | Main body | |
| 14 | Thermocouple | 2 | 1200℃ | Main body |
| 15 | Operational procedures | 1 | Main body |
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.