Mindray BC 5390 best automated hematology analyzer of blood
MODEL / Mindray BC 5390Mindray BC 5390 best automated hematology analyzer of blood. Welcome to medicalequipment-EKON.com.
- LAN Port supports HL7 protocol
Product Details
Quick Details
Large storage capacity: up to 100,000 samples, Support bi-directional LIS connection.
Specifications
Mindray BC 5390 best automated hematology analyzer of blood
BC-5390
Auto Hematology Analyzer

Technical Specifcations:
Principles
Impedance method for WBC/BAS, RBC and PLT counting;
Cyanide free reagent for hemoglobin test;
Flow Cytometry (FCM) + Laser scatter + Chemical dye method for
WBC differential analysis
Parameters
21 Reportable parameters: WBC, LYM(#,%), NEU(#,%), MON (#,%), EOS (#,
%), BAS (#,%), RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT,
MPV
10 Research parameters: ALY(#,%),LIC(#,%),NRBC(#,%),PDW,PCT,P-
LCC,P-LCR
3 Histograms and 1 scattergram
Analysis Mode
Autoloader Whole Blood Mode
Closed Whole Blood Mode
Closed Predilute Mode
Throughput
Up to 60 samples per hour with autoloader
Up to 51 samples per hour with closed mode
Up to 53 samples per hour with predilute mode
Sample Volume
Whole Blood CBC+DIFF 33 μL
Whole Blood CBC 24 μL
Prediluted: 20 μL
Test Panel
CBC CBC+DIFF
Performance
Carryover Precision Linearity
WBC (x 10 3 /μL) ≤ 1.0% ≤ 0.15 (SD) or 3.0% (CV%) 0.3-200
RBC (x 10 6 /μL) ≤ 1.0% ≤ 1.5% 0.2-8.0
HGB (g/dL) ≤ 1.0% ≤ 1.5% 0.5-25
HCT (%) ≤ 1.0% ≤ 2.0% 2 -75
PLT (x 10 3 /μL) ≤ 1.0% ≤ 7.5 (SD) or 5.0% (CV%) 5-2000

Mindray BC 5390 best automated hematology analyzer of blood
Data Storage Capacity
Up to 100,000 results including numeric and
graphical information
Communication
LAN Port supports HL7 protocol
Operating Environment
Temperature: 15 °C~30°C
Humidity: 30~85%
Air Pressure: 70~106 kPa
Power Requirement
A.C.100-240V ≤ 300VA 50/60Hz
Dimension and Weight
Dimension (WxDxH, inches): 22.4 x 23.2 x 20.6
Weight: ≤ 143 pounds

MSL TEAM picture
Welcome to medicalequipment-msl.com.
Technical Specifications
Technical parameters from the currently available product information.
- Large storage capacity
- up to 100,000 samples, Support bi-directional LIS connection.
- Reportable parameters
- WBC, LYM(#,%), NEU(#,%), MON (#,%), EOS (#
- Research parameters
- ALY(#,%),LIC(#,%),NRBC(#,%),PDW,PCT,P-
- Prediluted
- 20 μL
- Temperature
- 15 °C~30°C
- Humidity
- 30~85%
- Air Pressure
- 70~106 kPa
- Dimension (WxDxH, inches)
- 22.4 x 23.2 x 20.6
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.