Lab Equipment > Mindray analyzer

Mindray BC 6200 automated hematologi analyzer

MODEL / Mindray BC 6200

Mindray BC-6200 fulflls all these requirements and exceeds your expectations with so much more in terms of Value, Operation and Cost.

PRODUCT OVERVIEW

Product Details

Quick Details

blood cell count

hematology cbc

hematologic system

Specifications

Mindray BC 6200 automated hematologi analyzer Principles

SF Cube* method to count WBC, 5-part dif, NRBC, RET and PLT-O

DC impedance method for RBC and PLT

Cyanide free reagent for hemoglobin test

*S: Scatter; F: Fluorescence; Cube: 3D analysis

blood cell count

Mindray BC 6200 automated hematologi analyzer Parameters

37 Reportable parameters (whole blood): WBC, Lym%, Mon%,

Neu%, Bas%, Eos%, IMG%, Lym#, Mon#, Neu#, Eos#, Bas#, IMG#;

RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, NRBC#,

NRBC%; PLT, MPV, PDW, PCT, P-LCR, P-LCC, RET%, RET#, RHE, IRF,

LFR, MFR, HFR, IPF

29 Research parameters (whole blood): HFC#, HFC%, RBC-O, PLT-O,

PLT-I, WBC-O, WBC-D, TNC-D, IME%, IME#, H-NR%, L-NR%, NLR, PLR,

WBC-N, TNC-N, InR#, InR‰, Micro#, Micro%, Macro#, Macro%, RPI,

H-IPF, IPF#, MRV, FRC#, FRC%, PDW-SD

7 Reportable parameters (body fuid): WBC-BF, TC-BF#, MN#, MN%,

PMN#, PMN%, RBC-BF

11 Research parameters (body fuid): Eos-BF#, Eos-BF%, Neu-BF#,

Neu-BF%, HF-BF#, HF-BF%, RBC-BF, LY-BF#, LY-BF%, MO-BF#,

MO-BF%

2 Histograms for RBC and PLT

3 Three-dimension scatter grams: DIFF, WNB, RET

5 Two-dimension scatter grams: DIFF, WNB, RET, RET-EXT, PLT-O

hematology cbc

Mode

CBC, CBC+DIFF, CBC+DIFF+RET, CBC+RET, RET

Data storage capacity

Up to 10,0000 results including numeric and graphical information

Operating environment

Temperature: 15℃~32℃

Humidity: 30%~85%

Sample volume

Whole blood (Autoloader, Closed Tube) 80uL

Capillary blood (Closed Tube) 35uL

Predilute (Closed Tube) 20uL

Body fuid (Closed Tube) 85uL

Throughput

Up to 110 samples per hour (CBC+DIFF)

Up to 65 samples per hour (RET)

Up to 40 samples per hour (Body fuid)

Loading capacity

Up to 50 sample tubes

hematologic system

At Mindray, we seek to understand the needs of every customer, and deliver tailor-made solutions. Before designing any product, we listen to the Voice Of Customers and bear in mind the challenges they face. In today’s laboratories, lab managers are looking for an analyzer with greater clinical values, such as higher fagging efciency to reduce the ratio of microscopic examination, NRBC/RET/body fuid results generated in a small-footprint system, among others, all within limited budget.

Mindray BC-6200 fulflls all these requirements and exceeds your expectations with so much more in terms of Value, Operation and Cost.

hematologi analyzer

In DIFF scattergram, BC-6200 not only gives WBC 5-part diferential results (with immature granulocyte), but also brings research parameters such as HFC (Blast & Atypical Lymphocyte), InR (information about malaria) and fags for Band, NRBC, PLT clump and Atypical Lymphocyte.

HFC*(#, %) parameters represent high population of fuorescent cell, such as Blasts and Atypical Lymphocytes.

IMG(#, %) parameters provide information about immature granulocytes, including Promyelocytes, Myelocytes,

Metamyelocytes, Immature Eosinophils and Immature Basophils.

BC-6200 provides a dedicated fag called “infected RBC?”, and “InR*(#,‰)”parameters to represent the number and ratio of the infected red blood cells in the sample respectively. BC-6200 users can obtain information about the possible presence of plasmodium parasite, the causative agent of malaria infection.

With the rising number of red blood cells with malaria parasites, the number of dots in the “InR” area increases proportionately. This creates the possibility to not only screen but also judge the severity of malaria infection.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

*S
Scatter; F: Fluorescence; Cube: 3D analysis
Reportable parameters (whole blood)
WBC, Lym%, Mon%
Research parameters (whole blood)
HFC#, HFC%, RBC-O, PLT-O
Reportable parameters (body fuid)
WBC-BF, TC-BF#, MN#, MN%
Research parameters (body fuid)
Eos-BF#, Eos-BF%, Neu-BF#
Three-dimension scatter grams
DIFF, WNB, RET
Two-dimension scatter grams
DIFF, WNB, RET, RET-EXT, PLT-O
Temperature
15℃~32℃
Humidity
30%~85%
Whole blood (Autoloader, Closed Tube)
80uL
Capillary blood (Closed Tube)
35uL
Predilute (Closed Tube)
20uL
Body fuid (Closed Tube)
85uL

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us