Self-checking function; Double needle dialysis; Liquid level detector.

  • Self-checking function
  • Double needle dialysis
  • Liquid level detector
  • Blood leakage detector
PRODUCT OVERVIEW

Product Details

Quick Details

Self-checking function

Carbonate dialysis

Double needle dialysis

Liquid level detector

Specifications

Mobile blood Dialysis Machine EKONHM01

MSL Mobile blood Dialysis Machine EKONHM01

MSL blood Dialysis Machine EKONHM01 Main performance of this device:

1. Self-checking function;

2. Carbonate dialysis;

3. Double needle dialysis;

4. Liquid level detector;

5. Bubble detector;

6. Blood leakage detector;

7. Temperature and electric conductivity monitoring;

8. Arterial pressure, venous pressure and transmembrane pressure monitoring;

9. Rolling blood pump;

10. Heparin pump;

11. Dehydration amount controlled by capacity;

12. Automatic disinfection cleaning program;

13. Stand-by power of blood pump in case of power failure;

14. Information display function of display screen.

*This device is designed and manufactured in strict accordance with the

Requirements of national laws and regulations. The reference standards of design and manufacture are following:

GB9706.1-2007; GB9706.2-2003; and YY0054-2003.

blood Dialysis Machine EKONHM01

Cheap Mobile blood Dialysis Machine EKONHM01 Technical Parameter

Size &Weight:

Size: 380mmx400x1380mm (L*W*H);

Area: 500*520mm;

Weight: 88KG;

Power supply:

AC220V, 50Hz/60Hz, 10A

Input power: 1500W

Back-up battery: 30 minutes

Best Mobile blood Dialysis Machine EKONHM01 Working Condition:

Water input pressure: 0.1Mpa~0.6Mpa, 15P.S.I~60P.S.I

Water input temperature: 5℃~30℃

Working environment temperature: 10℃~30℃ at relative humidity ≦70%

UF rate:

Flow range: 0ml/h~4000ml/h

Resolution ratio: 1ml

Precision: ±30ml/h

Blood pump &Spare pump:

Blood pump flow range: 30ml/min~600ml/min (diameter: 8mm or 6mm)

Spare pump flow range: 30ml/min~600ml/min (diameter 8mm or 6mm)

Resolution ratio: 0.1ml

Precision: ±10ml or 10% of reading

Heparin pump:

Syringe size: 20, 30, 50ml

Flow range: 0ml/h~10ml/h

Resolution ratio: 0.1ml

Precision: ±5%

Monitoring system &Alarm set up:

Venous pressure: -180mmHg ~ +600mmHg, ±10mmHg

Arterial pressure: -380mmHg ~ +400mmHg, ±10mmHg

TMP pressure: -180mmHg ~ +600mmHg, ±20mmHg

Dialysate temperature: preset range 34.0℃~39.0℃

Blood leak detection: Photo chromic alarm when erythrocyte specific volume is 0.32±0.02 or blood leak volume is equal or more than 1ml per liter of dialysate.

Bubble detection: Ultrasonic, Alarm when a single air bubble volume is more than 200μl at 200ml/min blood flow

Conductivity: Acoustic-optic

Use Mobile blood Dialysis Machine EKONHM01 Disinfection/Sanitize:

1. Heat disinfection:

Time: 30 minutes; Temperature: about 80℃, at flow rate 500ml/min;

2. Chemical disinfection:

Time: 30minutes, Temperature: about 36℃~50℃, at flow rate 500ml/min;

3. Chemical disinfection with heat:

Time: 45minutes, Temperature: about 36℃~80℃, at flow rate 50ml/min;

4. Rinse:

Time: 10minutes, Temperature: about 37℃, at flow rate 800ml/min;

Storage Environment:

Storage temperature should be between 5℃~40℃, at relative humidity ≦80%

what will you get?

what will you get
TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Area
500*520mm
Input power
1500W
Back-up battery
30 minutes
Water input pressure
0.1Mpa~0.6Mpa, 15P.S.I~60P.S.I
Water input temperature
5℃~30℃
Working environment temperature
10℃~30℃ at relative humidity ≦70%
Flow range
0ml/h~4000ml/h
Resolution ratio
1ml
Precision
±30ml/h
Blood pump flow range
30ml/min~600ml/min (diameter: 8mm or 6mm)
Spare pump flow range
30ml/min~600ml/min (diameter 8mm or 6mm)
Syringe size
20, 30, 50ml
Venous pressure
-180mmHg ~ +600mmHg, ±10mmHg
Arterial pressure
-380mmHg ~ +400mmHg, ±10mmHg
TMP pressure
-180mmHg ~ +600mmHg, ±20mmHg
Dialysate temperature
preset range 34.0℃~39.0℃
Blood leak detection
Photo chromic alarm when erythrocyte specific volume is 0.32±0.02 or blood leak volume is equal or more than 1ml per liter of dialysate.
Bubble detection
Ultrasonic, Alarm when a single air bubble volume is more than 200μl at 200ml/min blood flow