Neonata transcutaneous jaundice meter | jaundice test EKONJM02
MODEL / EKONJM02Neonata transcutaneous jaundice meter | jaundice test EKONJM02. Welcome to medicalequipment-EKON.com.
- A high-tech product by the use of the advanced optical fiber and photoelectronic
- Detected quickly without any pain to the body
- Examined quickly without any pollution to be generated in use
- Highly bright LED in three digits to display
Product Details
Quick Details
Function features:
1.A high-tech product by the use of the advanced optical fiber and photoelectronic
data processing technologies
2.Detected quickly without any pain to the body
3.Examined quickly without any pollution to be generated in use
4.Highly bright LED in three digits to display
5.The value of transcutaneous jaundice can be measured out instantly at the unit of mg/dl
6.Elegant in appearance, small in volume, easy and safe for operation
Specifications
Neonata transcutaneous jaundice meter | jaundice test EKONJM02
Technical information
1.The measurement mode: light reflection
2.The display of measured result: display of data with LED in three digits
3.The measurement error: 00.0 --- 20.0±1, allowable error:±1.0
4.The light source: xenon flash lamp
5.The electric power: 600 mAH and DC 4.8 V rechargeable
6.The time ready for the instrument to start up: shorter than 5 seconds, after the
“READY” lamp has been on
7.The outer dimension: 165×65×40mm
8.The charger: input AC 220V at 50 Hz
output DC8V and 100 mA (no-load)
9.The check board: white color screen 00.0 + 1.0 and yellow screen 20.0±1.0

Neonata transcutaneous jaundice meter | jaundice test EKONJM02
Function features:
1.A high-tech product by the use of the advanced optical fiber and photoelectronic
data processing technologies
2.Detected quickly without any pain to the body
3.Examined quickly without any pollution to be generated in use
4.Highly bright LED in three digits to display
5.The value of transcutaneous jaundice can be measured out instantly at the unit of mg/dl
6.Elegant in appearance, small in volume, easy and safe for operation

Neonata transcutaneous jaundice meter | jaundice test EKONJM02
Operate Environment
The temperature scope 5℃~40℃
The relative humidity ≤80%
The atmosphere pressure 86.0 kpa ----106.0 kpa

MSL TEAM picture
Welcome to medicalequipment-msl.com.
Technical Specifications
Technical parameters from the currently available product information.
- The measurement mode
- light reflection
- The display of measured result
- display of data with LED in three digits
- The measurement error
- 00.0 --- 20.0±1, allowable error:±1.0
- The light source
- xenon flash lamp
- The electric power
- 600 mAH and DC 4.8 V rechargeable
- The time ready for the instrument to start up
- shorter than 5 seconds, after the
- The outer dimension
- 165×65×40mm
- The charger
- input AC 220V at 50 Hz
- output DC8V and
- 100 mA (no-load)
- The check board
- white color screen 00.0 + 1.0 and yellow screen 20.0±1.0
- The relative humidity
- ≤80%
- The atmosphere pressure
- 86.0 kpa ----106.0 kpa
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.