Lab Equipment

Neonata transcutaneous jaundice meter | jaundice test EKONJM02

MODEL / EKONJM02

Neonata transcutaneous jaundice meter | jaundice test EKONJM02. Welcome to medicalequipment-EKON.com.

  • A high-tech product by the use of the advanced optical fiber and photoelectronic
  • Detected quickly without any pain to the body
  • Examined quickly without any pollution to be generated in use
  • Highly bright LED in three digits to display
PRODUCT OVERVIEW

Product Details

Quick Details

Function features:

1.A high-tech product by the use of the advanced optical fiber and photoelectronic

data processing technologies

2.Detected quickly without any pain to the body

3.Examined quickly without any pollution to be generated in use

4.Highly bright LED in three digits to display

5.The value of transcutaneous jaundice can be measured out instantly at the unit of mg/dl

6.Elegant in appearance, small in volume, easy and safe for operation

Specifications

Neonata transcutaneous jaundice meter | jaundice test EKONJM02

Technical information

1.The measurement mode: light reflection

2.The display of measured result: display of data with LED in three digits

3.The measurement error: 00.0 --- 20.0±1, allowable error:±1.0

4.The light source: xenon flash lamp

5.The electric power: 600 mAH and DC 4.8 V rechargeable

6.The time ready for the instrument to start up: shorter than 5 seconds, after the

“READY” lamp has been on

7.The outer dimension: 165×65×40mm

8.The charger: input AC 220V at 50 Hz

output DC8V and 100 mA (no-load)

9.The check board: white color screen 00.0 + 1.0 and yellow screen 20.0±1.0

jaundice meter

Neonata transcutaneous jaundice meter | jaundice test EKONJM02

Function features:

1.A high-tech product by the use of the advanced optical fiber and photoelectronic

data processing technologies

2.Detected quickly without any pain to the body

3.Examined quickly without any pollution to be generated in use

4.Highly bright LED in three digits to display

5.The value of transcutaneous jaundice can be measured out instantly at the unit of mg/dl

6.Elegant in appearance, small in volume, easy and safe for operation

jaundice meter

Neonata transcutaneous jaundice meter | jaundice test EKONJM02

Operate Environment

The temperature scope 5℃~40℃

The relative humidity ≤80%

The atmosphere pressure 86.0 kpa ----106.0 kpa

jaundice meter

MSL TEAM picture

Welcome to medicalequipment-msl.com.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

The measurement mode
light reflection
The display of measured result
display of data with LED in three digits
The measurement error
00.0 --- 20.0±1, allowable error:±1.0
The light source
xenon flash lamp
The electric power
600 mAH and DC 4.8 V rechargeable
The time ready for the instrument to start up
shorter than 5 seconds, after the
The outer dimension
165×65×40mm
The charger
input AC 220V at 50 Hz
output DC8V and
100 mA (no-load)
The check board
white color screen 00.0 + 1.0 and yellow screen 20.0±1.0
The relative humidity
≤80%
The atmosphere pressure
86.0 kpa ----106.0 kpa

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us