Surgery
Omron Electronic Blood Pressure Monitor HEM-1000
MODEL / HEM-1000On the condition that Temperature is 23℃;circumference of arm :250mm; Pressure: 170mmHg(22.7kPa), Battery can be used 250 times .
PRODUCT OVERVIEW
Product Details
Quick Details
Specifications
Omron Electronic Blood Pressure Monitor HEM-1000

Omron Electronic Blood Pressure Monitor HEM-1000




Omron Electronic Blood Pressure Monitor HEM-1000
MSL TEAM picture
Welcome to medicalequipment-msl.com.
TECHNICAL DATA
Technical Specifications
Technical parameters from the currently available product information.
| Product Name | Electronic l Blood Pressure Monitor |
| Model | HEM-1000 |
| Display | LED |
| Measuring way | Oscillographic Determination Method |
| Measuring Range | Blood pressure:0~299mmHg(0~39.9kpa) |
| Heart rate:40~180 times/minute | |
| Accuracy | Blood pressurre:+ 3mmHg(+0.4kPa) |
| Heart Rate:+5% | |
| Pressure measurement | Pressure Sensor |
| Power Supply | AA 6V dry cell (4 PIECES), Power Adapter (AC 100V~240V) |
| Battery Life | On the condition that Temperature is 23℃;circumference of arm:250mm; Pressure: 170mmHg(22.7kPa), Battery can be used 250 times. |
| Product Name | Electronic l Blood Pressure Monitor |
| Model | HEM-1000 |
| Display | LED |
| Measuring way | Oscillographic Determination Method |
| Measuring Range | Blood pressure:0~299mmHg(0~39.9kpa) |
| Heart rate:40~180 times/minute | |
| Accuracy | Blood pressurre:+ 3mmHg(+0.4kPa) |
| Heart Rate:+5% | |
| Pressure measurement | Pressure Sensor |
| Power Supply | AA 6V dry cell (4 PIECES), Power Adapter (AC 100V~240V) |
| Battery Life | On the condition that Temperature is 23℃;circumference of arm:250mm; Pressure: 170mmHg(22.7kPa), Battery can be used 250 times. |
| Available Humidness and temperature | +5℃——+40℃ · 15% RH——85%RH |
| Humidness and temperature of transportation and Preservation | -20℃ ~+60℃·10%RH~95%RH |
| Atmospheric Pressure during measurement | 700hPa~1060hPa |
| Atmospheric Pressure of transportation and Preservation | 500hpa~1060hPa |
| Measurable Circumference of arm | 170mm——320mm |
| Self-weight | 1500g(Without battery) |
| Dimension | 230*217*228mm |
| Protection against electric shock | Class II medical device,Type B Applied Part |
| Protection classification of liquid | Conventional Equipment |
| Disinfection | Clean as the request of manufacture |
| Security Classification | Can’t be used in gax mixture of flammable anesthetic atmosphere or oxygen or N2O. |
| Working System Classification | Continuous operation |
| Electro Magnetic Compatibility(EMC) | Group 1,Class B |
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.