On-line double beam scanning UV-Vis spectrophotometer EKONUV07
MODEL / EKONUV07On-line double beam scanning UV-Vis spectrophotometer EKONUV07. ?Dynamic testing, enzyme kinetics reaction rate.
- ?DNA \ RNA, protein test function: built-in specified formula to get the final result directly
- USB data interface with online dedicated PC workstation, with more powerful function and data processing capabilities.
- 5nm,1nm,2nm,4nm,5nm(Varible)
- EKON Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods? arrive destination safely and quickly.
Product Details
Quick Details
Function
Variable bandwidth, suitable for different samples and different test requirements
Photometric measurements: sample can be easily measured absorbance and transmittance at the specified wavelength. Multi-wavelength pinpoint
test can be simultaneously test up to 30 wavelengths
Quantitative analysis: automatically build standard curve, optional one-class and zero-class linear regression, second-class and third-class curve fitting, single and double wavelength calibration and three-point method; with store standard curve to facilitate future testing
Qualitative Analysis: The scanning speed is adjustable, filter position can be fine-tuned, spectrum processing including scaling, smoothing, filtering, peak detection etc
Dynamic testing, enzyme kinetics reaction rate.
DNA \ RNA, protein test function: built-in specified formula to get the final result directly
USB data interface with online dedicated PC workstation, with more powerful function and data processing capabilities.
Specifications
On-line double beam scanning UV-Vis spectrophotometer EKONUV07

On-line double beam scanning UV-Vis spectrophotometer EKONUV07
EKONUV07 double beam scanning UV-visible spectrophotometer is designed by Philes for professional customers who need high requirements of accurate measurement in the organic chemistry, biochemistry, pharmaceutical analysis, food testing, medicine and health, environmental protection, life sciences and other fields of scientific research and production. Using the latest technology and electronic control systems, optimizing the traditional optical design and structural design to make sure the accuracy, stability, durability while expand new functionality; original Heraeus deuterium lamp imported from German to ensure the stability and reliability.
Function
Variable bandwidth, suitable for different samples and different test requirements
Photometric measurements: sample can be easily measured absorbance and transmittance at the specified wavelength. Multi-wavelength pinpoint
test can be simultaneously test up to 30 wavelengths
Quantitative analysis: automatically build standard curve, optional one-class and zero-class linear regression, second-class and third-class curve fitting, single and double wavelength calibration and three-point method; with store standard curve to facilitate future testing
Qualitative Analysis: The scanning speed is adjustable, filter position can be fine-tuned, spectrum processing including scaling, smoothing, filtering, peak detection etc
Dynamic testing, enzyme kinetics reaction rate.
DNA \ RNA, protein test function: built-in specified formula to get the final result directly
USB data interface with online dedicated PC workstation, with more powerful function and data processing capabilities.
Performance feature
Light source correction mechanism, the light source will be locating the best position when self-testing each time so that it can fix the offset focus position possibly caused by vibration during the transportation and the user don’t have to debugging light source after change it
With rigorous optical system design and circuit control system design, strict selection of components, with high standards of accuracy, repeatability, low noise and low stray light indicators, and excellent the linear range and stability index
With open sample chamber, optional reflective sample holder, automatic 4-positon cell holder, 7-position and 16-position cell holder, solid sample holder, water bath and auto sampler etc suitable for different applications
On-line double beam scanning UV-Vis spectrophotometer EKONUV07

There are other types of UV-Vis spectrophotometer: EKONUV08, EKONUV09, EKONUV10, EKONUV11, EKONUV12, EKONUV13, EKONUV14.
MSL TEAM picture
Welcome to medicalequipment-msl.com,If you have any demand in ultrasound machine.
Technical Specifications
Technical parameters from the currently available product information.
| Specifications | ||
| Models | EKONUV07 | |
| Operation Mode | Host or PC operating including on-line software | |
| Wavelength Range | 190 - 1100nm | |
| Spectral Bandwidth | 0.5nm,1nm,2nm,4nm,5nm(Varible) | |
| Optical System | Double beam, Czerny-Turner, Grating 1200line/mm | |
| Wavelength Accuracy | ±0.1 nm(656.1 nm D2),±0.3 nm (the whole wavelength range) | |
| Wavelength Repeatability | ±0.1nm | |
| Wavelength Resolution | 0.1nm | |
| Photometric Range | -4 to 4A; 0-200%T; -9999 to 9999C | |
| Photometric Accuracy | ±0.002A(0~0.5A);±0.004A(0.5~1A);±0.3%T(0~100%T) | |
| Photometric Repeatability | ±0.001A(0~0.5A);±0.002A(0.5~1A);±0.15%T(0~100%T) | |
| Stray light | ≤ 0.02%T (220 nm,NaI;340 nm,NaNO2) | |
| Baseline Flatness | ±0.0008A(190~1100nm) | |
| Stability | ±0.0004A/hr @500nm,0A | |
| Photometric noise | ±0.0003A | |
| Data Output | 320×240 array graphic LCD | |
| USB connect to upper software | ||
| Power | 120W(kV:80V~250V) | |
| Size | 640*520*260 | |
| Weight | 25kg | |
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.