Surgery

Portable Dental Nitrous Oxide Systems Equipment EKONZT01

MODEL / EKONZT01

Easy to use with touch screen, easy to move with 4 casters. Do not need to be operated by anesthetist, any experienced nurse can do it.

  • Easy to use with touch screen, easy to move with 4 casters. Do not need to be operated by anesthetist, any experienced nurse can do it.
  • 4” TFT LCD touch screen displays the Ventilation parameters, Alarm information and Oscillogram. Multiple ventilation modes, suitable for different clinical needs. Electronic control mixed gas blender, high precision adjustment. In-built gas concentration monitoring system, real-time monitoring of airway pressure.
  • Rapid oxygen supply
  • Rapid oxygen flow 25L/min - 75L/min
PRODUCT OVERVIEW

Product Details

Quick Details

Simplicity

Easy to use with touch screen, easy to move with 4 casters. Do not need to be operated by anesthetist, any experienced nurse can do it.

Euectiveness

The onset of action for N2O is between 2-5 minutes. So it's a very quick-acting inhaled sedation medicine that decreases discomfort and anxiety.

10.4” TFT LCD touch screen displays the Ventilation parameters, Alarm information and Oscillogram. Multiple ventilation modes, suitable for different clinical needs. Electronic control mixed gas blender, high precision adjustment. In-built gas concentration monitoring system, real-time monitoring of airway pressure.

Specifications

TECHNICAL SPECIFICATION

Ventilation mode

  • Continuous gas supply
  • On-demand gas supply
  • Rapid oxygen supply
  • Manual

Ventilatorion parameter range

Oxvgen concentration 30%- 100%

Nitrous oxide concentration 0%- 70%,

On-demand gas 0-30Lmin.

Pressure trigger (RtW) -1cmH2O ~ -10cmH2O

Gas supply time 1s- 6S

Peak flow ≥601 /min.

Manual ventilation flow 0- 30L /min

Rapid oxygen flow 25L/min - 75L/min

Pressure limit 5cmH2O- 60cmH2O

Monltorlng parameter

Oxygen concentration 30%- 100%.

Ainway pressure 0- 60cmH2O.

Flow 0- 30L/min.

Oscillogram

P-T (pressure - time)

Alarm and protectlon

The AC power failure alarm Power failure or no cocnio

Builin badkup bttery low vllage <11.3土0.3V

High oxygen concentration alarm 31% - 100%,

Low axygen concentration alarm 30% - 99%,

High ainway pressure alarm 5cmH2O - 60cmHO

Pressure limit 0cmH2O - 60cmHO

Emergency ar Input when machine mafunction

Nitrous axide dlosure function Whenoxygenpressures200kPa

Low gas source input pressure Pressure s 200kPa

Working conditlons

Gas source O2, N2O

Pressure 280kPa - 600kPa

Voltage 110V - 240V.

Power frequency 50/60Hz.

Size

Wooden case packing size L 570 * W 780 * H 1400 mm

G.W 80KG

NW 35KG

Wooden case packing size L 465 * W 465 * H 505 mm

G.W 37KG

N.W 15K

Total CBM 0.73m3

Nitrous Oxide Sedation System EKONZT01-1

Other models for your reference :

EKONZT02

MZLST03

EKONZT04

Applicable department

  • Stamatolgaical Department
  • Gastroenterology Department
  • Obstetricse
  • Burn Department
  • Cosmetology Department
  • Oncology Department
  • Emergency Department
  • Othmaedics Department

Application

Nitrous Oxide Sedation System has been widely used in clinical practice for 160 years. It produces analgesic (pain killing) and anxiolytic (anxiety reduction) effects. Our Nitrous Oxide Sedation System makes a good performance in gastrointestinal endoscope department, obstetrics department, dentistry department and other departments. Perlove Medical Nitrous Oxide Sedation System can offer you the choices that you need in ventilation mode, monitoring and technique support.

Safety

Nitrous oxide has low solubility in blood, diffuses rapidly across the alveolar-arterial membrane and is excreted unchanged through the lungs. Nitrous oxide produces either no change, or a slight increase in blood pressure, while all other volatile anesthetics reduce blood pressure. Our machine also has multiple parameters monitoring interface which make every parameter clear, let users know the patient conditions in all aspects.

Euectiveness

The onset of action for N2O is between 2-5 minutes. So it's a very quick-acting inhaled sedation medicine that decreases discomfort and anxiety.

Simplicity

Easy to use with touch screen, easy to move with 4 casters. Do not need to be operated by anesthetist, any experienced nurse can do it.

Common Procedures Completed with Nitrous Oxide Sedation System

  • VCUG/RNC+
  • PICC Lines
  • ISAT
  • IV Starts
  • CT Scans
  • Elestromvelograms
  • Gastrostomy
  • Botulinum
  • Barium Enemas
  • Joint Injections
  • Incision and Drainage
  • Catheter Insertions
  • Childbirthe
  • Sutures
  • Lumbar Punctures

10.4” TFT LCD touch screen displays the Ventilation parameters, Alarm information and Oscillogram. Multiple ventilation modes, suitable for different clinical needs. Electronic control mixed gas blender, high precision adjustment. In-built gas concentration monitoring system, real-time monitoring of airway pressure.

Nitrous Oxide Sedation System EKONZT01-2

Electronic flowmneter of O2, N2O Rapid O2 supply can promote and mixed gas.

rapid revival of patients:

Electronic pressure gauges of O2 and N2O

Oscillogram of P-T (pressure-time) monitoring of airway pressure.

We offer 3 types of integrated breathing circuit which ensures easy AGSS keeps indoor

operation and keeps tidy. You can choose one of them. air clean.

Casters with brake make sure the device stable without moving.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Easy to use with touch screen, easy to move with
4 casters. Do not need to be operated by anesthetist, any experienced nurse can do it.
Peak flow
≥601 /min.
Manual ventilation flow
0- 30L /min
Rapid oxygen flow
25L/min - 75L/min
Pressure limit
5cmH2O- 60cmH2O
Ainway pressure
0- 60cmH2O.
Flow
0- 30L/min.
High ainway pressure alarm
5cmH2O - 60cmHO
Low gas source input pressure Pressure s
200kPa
Pressure
280kPa - 600kPa
Voltage
110V - 240V.
Power frequency
50/60Hz.
Wooden case packing size L 570 * W 780 * H
1400 mm
Wooden case packing size L 465 * W 465 * H
505 mm

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.