Portable oxygen concentrator EKONZY33
MODEL / EKONZY33Adopt advanced pressure swing adsorption technology (PSA), advanced process flow and low energy consumption.
- The air is taken from nature.
- Adopt advanced pressure swing adsorption technology (PSA), advanced process flow and low energy consumption.
- Precautions for safe use
- When using this product, please observe the following safety precautions
Product Details
Quick Details
The following features: 1) The air is taken from nature. 2) Adopt advanced pressure swing adsorption technology (PSA), advanced process flow and low energy consumption. 3) The product has a novel shape design, simple operation, stable operation and convenient maintenance.
Specifications
Product Features:
Precautions for safe use:
When using this product, please observe the following safety precautions: 1.oxygen is a combustion-supporting gas,it is not allowed to use the oxygen generator in an environment with bright or dark fire source or with flammable or explosive danger. Smoking is strictly prohibited near the oxygen inhaler 2.It is not allowed to place the oxygen tube under the bedspread or seat cushion. when there is no oxygen absorption,turn off the power supply of the oxygen generator. 3.The power supply must meet the requirements for safe use of electricity. if the power supply does not meet the requirements, do not use oxygen generator. 4.Please turn off the power supply and unplug the power plug,before cleaning,maintaining or replacing the safety tube of the oxygen generator. 5.Improper use of power cord and plug may cause burns or other electric shock hazards. do not use if the power cord is damaged. To avoid danger, it must be replaced by a professional authorized by the manufacturer.Unplug the power plug. 6.Please select safe and qualified socket and wiring board with safety electrician. 7.It is forbidden to plug in or unplug the power supply with wet hands. It is forbidden to drag the machine through the traction oxygen absorption pipe or power line. 8.Personnel not authorized by the company shall not remove the cover for maintenance.

Use environment Ambient temperature: 10 ℃ ~ 40 ℃ Relative humidity:30% ~ 75% Atmospheric pressure:86.0kPa ~ 106.0kPa 220 -240V(+5/-10V) Power frequency: 50Hz ± 1Hz
Working conditions: Impurities in raw air ≤ 0.3 mg / cm 3 Oil content in the air ≤ 0.01 ppm The surrounding environment should be free of corrosive gases and strong magnetic fields
Product Features:
Display mode: digital tube display, English characters Timing function continuous running timing, timing running timing, automatic cumulative timing Atomization function Remote control function: infrared remote control operation
Technical indicators
Oxygen concentration(when the flow≤1 liter) 90 ± 3% (v / v) Carbon dioxide content ≤0.01% (v / v) Smell: Odorless Particle size of solid matter ≤10um Solid matter content ≤0.5mg / m 3
Product technical indicators: Adjustment range (1 ~ 7 L / min)可调 Running noise ≤60dB (A) Timer error ≤ ± 3% Input power: 150W Machine weight: about 6kg Outline size:274×174×342mm



Unpacking: Open the box from the top surface of the box, remove the foam, open the plastic bag, pull the back cover handle, and take out the oxygen generator.
Inspection: First check the oxygen generator for transportation damage, and then check the accessories and random documents according to the packing list.
Installation: 1) Before use, first loosen the bottom Velcro strap to avoid vibration of the air compressor. 2) Add water to the humidification Cup: in front of the oxygen generator, at the arc gap, extend the index finger into the humidification cup, and then pull out the humidification cup, remove the silica gel plug, add some pure water (the liquid level should be lower than the highest water level) into the cup, and then plug the humidification cup back into the two air holes of the front cover.
Technical Specifications
Technical parameters from the currently available product information.
- Ambient temperature
- 10 ℃ ~ 40 ℃
- Relative humidity
- 30% ~ 75%
- Atmospheric pressure
- 86.0kPa ~ 106.0kPa
- Power frequency
- 50Hz ± 1Hz
- Display mode
- digital tube display, English characters
- Oxygen concentration(when the flow≤1 liter) 90 ±
- 3% (v / v)
- Particle size of solid matter
- ≤10um
- Running noise
- ≤60dB (A)
- Timer error ≤ ±
- 3%
- Input power
- 150W
- Machine weight
- about 6kg
- Outline size
- 274×174×342mm
- Add water to the humidification Cup
- in front of the oxygen generator, at the arc gap, extend the index finger into the humidification cup, and then pull out the humidification cup, remove the silica gel plug, add some pure water (the liquid level should be lower than the highest water level) into the cup, and then plug the humidification cup back into the two air holes of the front cover.
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.