Purchase High Quality Bone Fracture Therapeutic Equipment EKONBF03
MODEL / EKONBF03Various physiological and pathological fracturet, delayed union, nonunion, bone defect.
- Improve the clinical symptoms of Avascular Necrosis
Product Details
Quick Details
One-channel output Intensity of treatment: 0~64,adjustable by step,Max output is 64,red and white output current as following 50mA±10% (500Ω load) Time of treatment: Auto: max value is 3o minutes, set by inter procedure. Manual: it is adjustable in 10~60 minutes,error is ±60 seconds。 Stability of output current:rate of change ≤5% Change period of difference frequency:15~30seconds Treatment model:endogenous current model Input power:≤100VA Working mode:continuously
Specifications
Specification of Bone Fracture Therapeutic Equipment EKONBF03:
One-channel output Intensity of treatment: 0~64,adjustable by step,Max output is 64,red and white output current as following 50mA±10% (500Ω load) Time of treatment: Auto: max value is 3o minutes, set by inter procedure. Manual: it is adjustable in 10~60 minutes,error is ±60 seconds。 Stability of output current:rate of change ≤5% Change period of difference frequency:15~30seconds Treatment model:endogenous current model Input power:≤100VA Working mode:continuously


Application of Bone Fracture Therapeutic Equipment EKONBF03:
Anti-inflammatory, detumescence and Analgesia after the surgery Various physiological and pathological fracturet, delayed union, nonunion, bone defect. Contusion of soft tissue, joint sprain and strain of lumbar muscles, lumbar disc herniation, shoulder bursitis and sciatica, nerve injury or inflammation caused by paralysis and peripheral nerve disorders. Improve the clinical symptoms of Avascular Necrosis



Technical Specifications
Technical parameters from the currently available product information.
- Intensity of treatment
- 0~64,adjustable by step,Max output is 64,red and white output current as following 50mA±10% (500Ω load)
- Auto
- max value is 3o minutes, set by inter procedure.
- Manual
- it is adjustable in 10~60 minutes,error is ±60 seconds。
- Stability of output current
- rate of change ≤5%
- Change period of difference frequency
- 15~30seconds
- Treatment model
- endogenous current model
- Input power
- ≤100VA
- Working mode
- continuously
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.