Other

Purchase Portable Postpartum Rehabilitation Instrument EKONPR06

MODEL / EKONPR06

It can bear the influence from open circuit and short circuit, the function is no weaken; Six-channel output, Basic Pulse wave is rectangle wave, Basic pulse frequency:800Hz±8%; When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output.

  • It can bear the influence from open circuit and short circuit, the function is no weaken.
  • Six-channel output, Basic Pulse wave is rectangle wave, Basic pulse frequency:800Hz±8%.
  • When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output
  • Lactation lack at Post partum
PRODUCT OVERVIEW

Product Details

Quick Details

Output pulse width:0.4ms±10% Single pulse electricity:>7μc Single pulse power: ≤300mJ Open-way output peak value:≤500Vp-p Max output range value:≤40V Output range adjustment: power output range is 0~260, increase or dis crease progressively in proper sequence, it is steady consecutively, Min output is 2%. Treat time:15-65 minutes,error is 1 minute, It can bear the influence from open circuit and short circuit, the function is no weaken. When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output Working mode: continuously Input:≤100VA

Specifications

EKONPR06 Postpartum Rehabilitation Instrument:

It is the Obstetrics and Gynecology treatment products, based on low frequency electric therapy theory and actual situation of low frequency pulse current treatment, set up several treatment according to the most optimal manner, controlled automatically by computer chip, stimulate the specific position of the human body by the special treatment of low-frequency,produce physical effect effect on specific parts of the body, and adjust the human body environment, to clear the breast tubes, promote milk secretion. accelerate the recovery of the uterus, promote postpartum urination, reduce postpartum pain,accelerate healing.and so on.

Purchase Portable Postpartum Rehabilitation Instrument EKONPR06
Purchase Portable Postpartum Rehabilitation Instrument EKONPR06

Configuration:

1.Six-channel output, Basic Pulse wave is rectangle wave, Basic pulse frequency:800Hz±8%. 2.Adjusting wave and frequency:trapezoid wave 0.5-10Hz,triangle wave 1-20Hz,bell wave 0.5-10Hz (no adjusting wave below 40) 3.Output pulse width:0.4ms±10% 4.Single pulse electricity:>7μc 5.Single pulse power: ≤300mJ 6.Open-way output peak value:≤500Vp-p 7.Max output range value:≤40V 8.Output range adjustment: power output range is 0~260, increase or dis crease progressively in proper sequence, it is steady consecutively, Min output is 2%. 9.Treat time:15-65 minutes,error is 1 minute, 10.It can bear the influence from open circuit and short circuit, the function is no weaken. 11.When output range is exceed 10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output 12.Working mode: continuously 13.Input:≤100VA

Purchase Portable Postpartum Rehabilitation Instrument EKONPR06
Purchase Portable Postpartum Rehabilitation Instrument EKONPR06

Application:

1.Lactation lack at Post partum 2.Dredge breast 3.Mammitis 4.The recovery of the uterus 5.Diastasis recti abdominis 6.Chronic pelvic inflammation and vaginal relaxation 7.Retention of urine 8.Postoperative analgesia 9.Pelvic floor muscle repair 10.Body recovery

Purchase Portable Postpartum Rehabilitation Instrument EKONPR06
TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Output pulse width
0.4ms±10%
Single pulse electricity
>7μc
Single pulse power
≤300mJ
Open-way output peak value
≤500Vp-p
Max output range value
≤40V
Output range adjustment
power output range is 0~260, increase or dis crease progressively in proper sequence, it is steady consecutively, Min output is 2%.
Treat time
15-65 minutes,error is 1 minute
When output range is exceed
10 mA or 10v,the pre-set must be in min value, or else, it has no output when re-turn on the power.non-output
Working mode
continuously
Input
≤100VA
Adjusting wave and frequency
trapezoid wave 0.5-10Hz,triangle wave 1-20Hz,bell wave 0.5-10Hz (no adjusting wave below 40)

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us