Lab Equipment

Real-Time PCR Detection System EKONPCR04 pcr machine price

MODEL / EKONPCR04

Real-Time PCR Detection System EKONPCR04 pcr machine price. Which real-time or digital PCR system is right for you?

  • supply,the highly improved instrument is available for a variety of scientific research and clinical
  • Data Automatic Analysis;Melting Curve Genotyping
  • Background Correction;Automatic Gain;Customized Parameters
  • Which real-time or digital PCR system is right for you?
PRODUCT OVERVIEW

Product Details

Quick Details

Real-Time PCR Detection System EKONPCR04 pcr machine price

Model:EKONPCR04 Sample Capacity:96-Well PCR plate,12×8-strip,96×0.2ml(Bottom Transparent) Dynamics Range:1~10^10 copies Excitation Wavelength:300-800nm Emission Wavelength:500-800nm Block Temp.Range:4~105 C(Minimum Increment:0.1 C),SOAK Low Temp.Conservation Function Heating/Cooling Rate:4.0 Cls(max) Temp. Control Accuracy:<0.1℃ Temp. Fluctuation:<±0.1℃ Temp.Uniformity:±0.3℃

Specifications

Real-Time PCR Detection System EKONPCR04:

Real-Time PCR Detection System EKONPCR04 pcr machine price is the newest product of Bioer's Real-Time PCRdetection system family.Based on LineGene familiy's tradition,LineGene 9600Plusperforms96samplecapacity,5 detection channels and wider temperature range.Adopting FERROTEC newest Peltier,fiber optic technology and a new global wide range power supply,the highly improved instrument is available for a variety of scientific research and clinical applications.

Real-Time PCR Detection System EKONPCR04 pcr machine price
Real-Time PCR Detection System EKONPCR04 pcr machine price

Real-Time PCR Detection System EKONPCR04 pcr machine price Technical Parameters:

Product Name:LincGenc9600 Plus Fluorescence Quantitative PCR Detection System Model:EKONPCR04 Sample Capacity:96-Well PCR plate,12×8-strip,96×0.2ml(Bottom Transparent) Dynamics Range:1~10^10 copies Excitation Wavelength:300-800nm Emission Wavelength:500-800nm Block Temp.Range:4~105 C(Minimum Increment:0.1 C),SOAK Low Temp.Conservation Function Heating/Cooling Rate:4.0 Cls(max) Temp. Control Accuracy:<0.1℃ Temp. Fluctuation:<±0.1℃ Temp.Uniformity:±0.3℃ Temp.Control Mode:BLOCK/Tube Simulation Mode(Automatic Control Based On Sample Volume) Sample Volume Range:5~100uL Gradient Temp.Range:1~36 C Hot-lid Temp.Range:30~110℃(Adjustable,Default 105 C),Automatic Hot-lid Fluorescence Detection Repeatability:5% Scan Mode:Entire Plate or Designated Line Program:Max 20 Segments for Each Program,Max 99 Cycles Operation Mode:Continuous Scan Period:5.5s

Real-Time PCR Detection System EKONPCR04 pcr machine price
Real-Time PCR Detection System EKONPCR04 pcr machine price

Real-Time PCR Detection System EKONPCR04 pcr machine price Feature Function:

Absolute Quantification.Relative Quantification.SNP Analysis; Data Automatic Analysis;Melting Curve Genotyping; Gradient;HRM;Multi-channel Crosstalk Correction; Background Correction;Automatic Gain;Customized Parameters; Operation System:Microsoft: Windows7/windows 8.1,Software: Excel2000/2002/2003/200712012 PC Configuration:Memory: 2G Hard Disk: 32GB Power Supply:100-240V~5O/60Hz 600w Dimension(L>W×H):410mm×386mm×352mm Socket:USB Adapter,RS232 Adapter,Bluetooth Adapter Authentication:Ferrotec PeltierlCE(EMC &LVD)/IVD/RoHS2/PICC,product quality liability insurance

Real-Time PCR Detection System EKONPCR04 pcr machine price

Which real-time or digital PCR system is right for you?

To understand why traditional PCR is limited, it is important to understand what happens during the PCR reaction. A basic PCR run can be divided into three phases:

Index period

Accumulated product exactly doubles with each cycle (assuming 100% reaction efficiency). The reaction is highly specific and precise. Exponential amplification occurs because all reagents are freshly available and the kinetics of the reaction drive the reaction in favor of amplicon doubling.

Linear phase (high variability) As the reaction continues, some reagents are consumed by amplification. The reaction starts to slow down, and the PCR product no longer doubles with each cycle.

Plateau (endpoint: gel detection using conventional methods) The reaction stops, no more product is produced, and if left long enough, the PCR product will start to degrade. Because each sample has different reaction kinetics, each tube or reaction will plateau at a different time point. These differences can be seen during the plateau. During the plateau period, conventional PCR performs the measurement, also known as endpoint detection.

Variation in plateau measurements with conventional PCR Three replicate samples had the same amount of DNA at the start of the reaction and different amounts of PCR product during the plateau phase of the reaction (due to changes in reaction kinetics). Therefore, it will be more accurate to make measurements during the exponential period, where replicate samples expand exponentially.

Real-time PCR measures during exponential phase for more accurate quantitation Real-time PCR focuses on the exponential phase because it provides more precise data for quantification. During the exponential period, the real-time PCR instrument calculates two values. The threshold line is the level of detection at which the fluorescence intensity of the reaction exceeds background. The PCR cycle at which the sample reaches this level is called the cycle threshold (Ct). Ct values are used for downstream quantification or presence/absence detection. By comparing the Ct values of a sample of unknown concentration with a series of standards, the amount of template DNA in an unknown reaction can be accurately determined.

Digital PCR counts individual molecules for absolute quantification Digital PCR works by splitting the sample into many individual real-time PCR reactions; some of these reactions contain the molecule of interest (positive) and others do not (negative). After PCR analysis, a fraction of the negative results are used to generate absolute results for the exact amount of target molecule in the sample without the need for reference standards or endogenous controls.

TECHNICAL DATA

Technical Specifications

Technical parameters from the currently available product information.

Sample Capacity
96-Well PCR plate,12×8-strip,96×0.2ml(Bottom Transparent)
Dynamics Range
1~10^10 copies
Excitation Wavelength
300-800nm
Emission Wavelength
500-800nm
Block Temp.Range
4~105 C(Minimum Increment:0.1 C),SOAK Low Temp.Conservation Function
Heating/Cooling Rate
4.0 Cls(max)
Temp. Control Accuracy
<0.1℃
Temp. Fluctuation
<±0.1℃
Temp.Uniformity
±0.3℃
Temp.Control Mode
BLOCK/Tube Simulation Mode(Automatic Control Based On Sample Volume)
Sample Volume Range
5~100uL
Gradient Temp.Range
1~36 C
Hot-lid Temp.Range
30~110℃(Adjustable,Default 105 C),Automatic Hot-lid
Fluorescence Detection Repeatability
5%
Scan Mode
Entire Plate or Designated Line
Program
Max 20 Segments for Each Program,Max 99 Cycles
Operation Mode
Continuous
Scan Period
5.5s

Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.

NEED A CONFIGURATION?

Discuss this product with our team

Share your application, destination, and required configuration for a project-specific response.

Contact Us