Top Fetal Doppler EKONJB08 for sale | Medsinglong
MODEL / EKONJB08Overall sensitivity at the distances 200mm from the face of the probe (Doppler frequency: 500±50Hz, Target velocity: 10cm/s~40cm/s): ≥90dB
Product Details
Quick Details
Safety: Complies with IEC 60601 1, EN 60601 1, EN60601-1-2, IEC 61266 Ultrasonic emitting frequency: 3MHz Overall sensitivity at the distances 200mm from the face of the probe (Doppler frequency: 500±50Hz, Target velocity: 10cm/s~40cm/s): ≥90dB Spatial-peak temporal-peak acoustic pressure: ≤1MPa Output power: <20mW
Specifications
Features of Fetal Doppler EKONJB08:
High sensitive ultrasound probe Detect the heart rates of 16th week fetus Record the fetal heart beat by computer


Specifications of Fetal Doppler EKONJB08:
Safety: Complies with IEC 60601 1, EN 60601 1, EN60601-1-2, IEC 61266 Ultrasonic emitting frequency: 3MHz Overall sensitivity at the distances 200mm from the face of the probe (Doppler frequency: 500±50Hz, Target velocity: 10cm/s~40cm/s): ≥90dB Spatial-peak temporal-peak acoustic pressure: ≤1MPa Output power: <20mW Effective area of the ultrasonic transducer active element:2.65cm2±0.3cm2 The acoustic coupling medium for normal use: ph: 5.5~8, Acoustic impedance: ≤1.7*105g /cm2·s Working mode: Continuous wave Doppler Audio output: Audio output power: <0.5 W Audio out Socket: Φ3.5mm/USB interface Stand-by Time: >4hours Suitable gestation: 16 gestational weeks or later, difference in pregnant mater. Physical Characteristic: Size: 104.5mm(length) * 50mm(width) * 70mm(height) Weight: 69.5g (only main unit, not including battery)


Medial & Video of Fetal Doppler EKONJB08
Technical Specifications
Technical parameters from the currently available product information.
- Safety
- Complies with IEC 60601 1, EN 60601 1, EN60601-1-2, IEC 61266
- Ultrasonic emitting frequency
- 3MHz
- Spatial-peak temporal-peak acoustic pressure
- ≤1MPa
- Output power
- <20mW
- Effective area of the ultrasonic transducer active element
- 2.65cm2±0.3cm2
- The acoustic coupling medium for normal use
- ph: 5.5~8, Acoustic impedance: ≤1.7*105g /cm2·s
- Working mode
- Continuous wave Doppler
- Audio output power
- <0.5 W
- Audio out Socket
- Φ3.5mm/USB interface
- Stand-by Time
- >4hours
- Suitable gestation
- 16 gestational weeks or later, difference in pregnant mater.
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.