Urine Sediment Analyzer Machine FUS-100 for sale | Medsinglong
MODEL / FUS-100Identify and classify by utilizing digital imaging technology,consistent with CLSlstandards; 810 frames of images for each sample; Flow cytometry technology,without centrifugation and staining, contributes to cost-effective.
- Identify and classify by utilizing digital imaging technology,consistent with CLSlstandards
- 810 frames of images for each sample
- Flow cytometry technology,without centrifugation and staining, contributes to cost-effective
- 12 categories of formed elements in urine can be identified accurately
Product Details
Quick Details
Parameter:Technical requirement Maximum Relative Deviation of the ResultAccuracy:≤士8.0% Repeatability of the Test ltems:CV≤10% Total Specificity (Automatic Identification):>80% Total Specificity(Manual Verification):≥95%
Specifications
Urine Sediment Analyzer FUS-100 Specifications and Technical Parameter:
Item:RBC,WBC,WBCC,SQEP,NSE,HYAL,UNCC,BACT,SPRM,MUCS,CRYS,YST Throughput:60 samples/h Sample Volume:Minimum volume:3mL non-centrifugeol urine ( Integrated system minimum volume:5mL,non-centrifuged urine); aspiration volume: about 1mL Test Principle:Flow cytometry;High-speed,High-depth of Field lmaging Technique Formed Element ldentification:Artificial intelligence identification technique Workstation:Quad-core processor,Windows operating system,Bidirectional to LIS/HIS. Data Storage:Storage capacity ≥10,000 Connecting:Available for connecting with DIRUl H-800 Automatic Urine Analyzer.Combined result printing. Printer:Hp laser printer

Equipment Parameter:
Parameter:Technical requirement Maximum Relative Deviation of the ResultAccuracy:≤士8.0% Repeatability of the Test ltems:CV≤10% Total Specificity (Automatic Identification):>80% Total Specificity(Manual Verification):≥95%
Working Condition:
Supply Voltage:AC100V~240V,50/6O Hz Environmental Temperature:10℃~30℃ Relative Humidity:20%~80% Atmospheric Pressure:860hPa~1060hPa
Features:
1.Identify and classify by utilizing digital imaging technology,consistent with CLSlstandards 2.810 frames of images for each sample 3.Flow cytometry technology,without centrifugation and staining, contributes to cost-effective 4.12 categories of formed elements in urine can be identified accurately
Technical Specifications
Technical parameters from the currently available product information.
- Maximum Relative Deviation of the ResultAccuracy
- ≤士8.0%
- Repeatability of the Test ltems
- CV≤10%
- Total Specificity (Automatic Identification)
- >80%
- Total Specificity(Manual Verification)
- ≥95%
- Throughput
- 60 samples/h
- Sample Volume
- Minimum volume:3mL non-centrifugeol urine ( Integrated system minimum volume:5mL,non-centrifuged urine); aspiration volume: about 1mL
- Test Principle
- Flow cytometry;High-speed,High-depth of Field lmaging Technique
- Data Storage
- Storage capacity ≥10,000
- Connecting
- Available for connecting with DIRUl H-800 Automatic Urine Analyzer.Combined result printing.
- Supply Voltage
- AC100V~240V,50/6O Hz
- Environmental Temperature
- 10℃~30℃
- Relative Humidity
- 20%~80%
- Atmospheric Pressure
- 860hPa~1060hPa
Specifications can vary by configuration. Confirm intended use, final model, and supply details with our product team.
Discuss this product with our team
Share your application, destination, and required configuration for a project-specific response.